IAC

B&R X20HB8815

POWERLINK Up to 2 slots for hub expansion modules 3x / 5x POWERLINK hub The POWERLINK TCP/IP gateway enables the exchange of all types of application data (HMI, diagnostics, parameter data, etc.) between a POWERLINK V2 network and a TCP/IP network. It functions like a layer 2 switch, with the exception that cyclic POWERLINK packets are not routed to the ETH port. With respect to the functionality of layer 2 switches, it should be mentioned that the gateway uses the store-and-forward principle. Gateway functionality doesn't need to be configured separately. When the gateway receives a frame, it saves the MAC address of the sender and the corresponding interface in the source address table (SAT). If the destination address is found in the SAT, the gateway routes the frame to the corresponding interface. Frames with a broadcast or multicast address are always routed to all interfaces. When IP packets are received at the "ETH" port that are larger than the MTU configured for POWERLINK, they are fragmented, if permitted. "ETH" port: Interface for TCP/IP network "PLK" port: Interface for POWERLINK network I/O modules cannot be operated with the X20HB8815. POWERLINK V1 is not supported. POWERLINK is a standard protocol for Fast Ethernet equipped with hard real-time characteristics. The POWERLINK Standardization Group (EPSG, see www.ethernet-powerlink.org) ensures its openness and continual development. The bus modules expanded to the left allow connection of up to 2 hub expansion modules in addition to the gateway. This means that a basic device provides up to 2 POWERLINK ports.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
GatewayPOWERLINK controlled node with up to 2 slots for hub expansion modules
General information
Diagnostics / Module statusYes, using LED status indicator and software
Diagnostics / Bus functionYes, using LED status indicator and software
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X
Certifications / ULcULus E115267 Industrial control equipment
Certifications / HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
Certifications / DNVTemperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)
Certifications / CCSYes
Certifications / LRENV1
Certifications / KRYes
Certifications / ABSYes
Certifications / BVEC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck
Certifications / KCYes
Status indicatorsModule status, bus function
Power consumption2 W
Interfaces
Transfer rate / POWERLINK100 Mbit/s
Transfer rate / TCP/IP10/100 Mbit/s
Transfer / POWERLINK / Physical layer100BASE-TX
Transfer / POWERLINK / Half-duplexYes
Transfer / POWERLINK / Full-duplexNo
Transfer / POWERLINK / AutonegotiationYes
Transfer / POWERLINK / Auto-MDI/MDIXYes
Transfer / TCP/IP / Physical layer10BASE-T/100BASE-TX
Transfer / TCP/IP / Half-duplexYes
Transfer / TCP/IP / Full-duplexYes
Transfer / TCP/IP / AutonegotiationYes
Transfer / TCP/IP / Auto-MDI/MDIXYes
TypePOWERLINK gateway
Execution2x shielded RJ45
Line lengthMax. 100 m between 2 stations (segment length)
Hub propagation delay0.96 to 1 µs
Electrical properties
Electrical isolationPower supply isolated from Ethernet (ETH1) and POWERLINK (PLK2)
Operating conditions
Mounting orientation / HorizontalYes
Mounting orientation / VerticalYes
Installation elevation above sea level / 0 to 2000 mNo limitation
Installation elevation above sea level / >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Horizontal mounting orientation-25 to 60°C
Temperature / Operation / Vertical mounting orientation-25 to 50°C
Temperature / Derating-
Temperature / Storage-40 to 85°C
Temperature / Transport-40 to 85°C
Relative humidity / Operation5 to 95%, non-condensing
Relative humidity / Storage5 to 95%, non-condensing
Relative humidity / Transport5 to 95%, non-condensing
Mechanical properties
Pitch / X20BB8037.5⁺⁰.² mm
Pitch / X20BB8162.5⁺⁰.² mm
Pitch / X20BB8287.5⁺⁰.² mm
NoteOrder 1x terminal block X20TB12 separately. Order 1x power supply module X20PS8002 separately. Order 1x bus base X20BB8x separately.

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.