B&R X20HB8815
POWERLINK Up to 2 slots for hub expansion modules 3x / 5x POWERLINK hub The POWERLINK TCP/IP gateway enables the exchange of all types of application data (HMI, diagnostics, parameter data, etc.) between a POWERLINK V2 network and a TCP/IP network. It functions like a layer 2 switch, with the exception that cyclic POWERLINK packets are not routed to the ETH port. With respect to the functionality of layer 2 switches, it should be mentioned that the gateway uses the store-and-forward principle. Gateway functionality doesn't need to be configured separately. When the gateway receives a frame, it saves the MAC address of the sender and the corresponding interface in the source address table (SAT). If the destination address is found in the SAT, the gateway routes the frame to the corresponding interface. Frames with a broadcast or multicast address are always routed to all interfaces. When IP packets are received at the "ETH" port that are larger than the MTU configured for POWERLINK, they are fragmented, if permitted. "ETH" port: Interface for TCP/IP network "PLK" port: Interface for POWERLINK network I/O modules cannot be operated with the X20HB8815. POWERLINK V1 is not supported. POWERLINK is a standard protocol for Fast Ethernet equipped with hard real-time characteristics. The POWERLINK Standardization Group (EPSG, see www.ethernet-powerlink.org) ensures its openness and continual development. The bus modules expanded to the left allow connection of up to 2 hub expansion modules in addition to the gateway. This means that a basic device provides up to 2 POWERLINK ports.
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
Short description
| Gateway | POWERLINK controlled node with up to 2 slots for hub expansion modules |
General information
| Diagnostics / Module status | Yes, using LED status indicator and software |
| Diagnostics / Bus function | Yes, using LED status indicator and software |
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / CRA (Cyber Resilience Act) | In preparation |
| Certifications / ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X |
| Certifications / UL | cULus E115267 Industrial control equipment |
| Certifications / HazLoc | cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
| Certifications / DNV | Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck) |
| Certifications / CCS | Yes |
| Certifications / LR | ENV1 |
| Certifications / KR | Yes |
| Certifications / ABS | Yes |
| Certifications / BV | EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck |
| Certifications / KC | Yes |
| Status indicators | Module status, bus function |
| Power consumption | 2 W |
Interfaces
| Transfer rate / POWERLINK | 100 Mbit/s |
| Transfer rate / TCP/IP | 10/100 Mbit/s |
| Transfer / POWERLINK / Physical layer | 100BASE-TX |
| Transfer / POWERLINK / Half-duplex | Yes |
| Transfer / POWERLINK / Full-duplex | No |
| Transfer / POWERLINK / Autonegotiation | Yes |
| Transfer / POWERLINK / Auto-MDI/MDIX | Yes |
| Transfer / TCP/IP / Physical layer | 10BASE-T/100BASE-TX |
| Transfer / TCP/IP / Half-duplex | Yes |
| Transfer / TCP/IP / Full-duplex | Yes |
| Transfer / TCP/IP / Autonegotiation | Yes |
| Transfer / TCP/IP / Auto-MDI/MDIX | Yes |
| Type | POWERLINK gateway |
| Execution | 2x shielded RJ45 |
| Line length | Max. 100 m between 2 stations (segment length) |
| Hub propagation delay | 0.96 to 1 µs |
Electrical properties
| Electrical isolation | Power supply isolated from Ethernet (ETH1) and POWERLINK (PLK2) |
Operating conditions
| Mounting orientation / Horizontal | Yes |
| Mounting orientation / Vertical | Yes |
| Installation elevation above sea level / 0 to 2000 m | No limitation |
| Installation elevation above sea level / >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature / Operation / Horizontal mounting orientation | -25 to 60°C |
| Temperature / Operation / Vertical mounting orientation | -25 to 50°C |
| Temperature / Derating | - |
| Temperature / Storage | -40 to 85°C |
| Temperature / Transport | -40 to 85°C |
| Relative humidity / Operation | 5 to 95%, non-condensing |
| Relative humidity / Storage | 5 to 95%, non-condensing |
| Relative humidity / Transport | 5 to 95%, non-condensing |
Mechanical properties
| Pitch / X20BB80 | 37.5⁺⁰.² mm |
| Pitch / X20BB81 | 62.5⁺⁰.² mm |
| Pitch / X20BB82 | 87.5⁺⁰.² mm |
| Note | Order 1x terminal block X20TB12 separately. Order 1x power supply module X20PS8002 separately. Order 1x bus base X20BB8x separately. |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
Manuals
3D CAD models
ECAD / EPLAN
Certificates
- 2226379 CSA Certificate of Compliance X20 X67
- 64331_A1 BV Certificate of Compliance X20
- 64331_A1 BV Certificate of Compliance X20(de)
- ABS Certificate of Product Design Assessment - X20 IO Series
- CCS Type Approval Certificate - X20
- E115267 UL Certificate of Compliance X20
- EU Data Act - X20 IO - Connected Product Information Notice
- EU Declaration ATEX X20
- EU Declaration of conformity PLC X20
- FTZU 09 ATEX 0083X
- KR Type Approval Certificate MIL39390-AC003 (X20 System)
- Lloyds Register (X20 only)
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.