B&R X20IF1086-2
POWERLINK for real-time Ethernet communication 100 Base-FX port Poll response chaining Dynamic Node Allocation (DNA) The interface module is used for application-specific expansion of the X20 controllers. It is equipped with a POWERLINK interface. This interface uses a 100 Base-FX port. The POWERLINK connection is made using 62.5/125 μm or 50/125 µm fiber optic multimode cable with a duplex LC connection. The module and network status is indicated using LEDs.
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
Short description
| Communication module | 1x POWERLINK (V1/V2) managing or controlled node |
General information
| Diagnostics / Module status | Yes, using LED status indicator and software |
| Diagnostics / Bus function | Yes, using LED status indicator and software |
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / CRA (Cyber Resilience Act) | In preparation |
| Certifications / ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X |
| Certifications / UL | cULus E115267 Industrial control equipment |
| Certifications / HazLoc | cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
| Certifications / CCS | Yes |
| Certifications / KC | Yes |
| B&R ID code | 0xB455 |
| Status indicators | Module status, bus function |
| Power consumption | 1.8 W (rev. <D0: 2 W) |
| Additional power dissipation caused by actuators (resistive) [W] | - |
Interfaces
| Transfer / Physical layer | 100BASE-FX |
| Transfer / Half-duplex | Yes |
| Transfer / Full-duplex | POWERLINK mode: No / Ethernet mode: Yes |
| Transfer / Autonegotiation | No |
| Transfer / Auto-MDI/MDIX | No |
| Optical power budget / Glass fiber 62.5/125 µm, NA = 0.275 | 11 dB |
| Optical power budget / Glass fiber 50/125 µm, NA = 0.200 | 7.5 dB |
| Line length / Ethernet TCP/IP | Max. 400 m between 2 stations (segment length) |
| Line length / POWERLINK | Max. 2 km between 2 stations (segment length) |
| Fieldbus | POWERLINK (V1/V2) managing or controlled node |
| Type | Type 4 |
| Standard (compliance) | ANSI/IEEE 802.3 |
| Variant | 1x duplex LC |
| Transfer rate | 100 Mbit/s |
| Controller | POWERLINK MAC |
| Wave length | Typ. 1300 nm Rx range: 1270 to 1380 nm Tx range: 1270 to 1380 nm |
| Cable fiber type | Multimode fiber with 62.5/125 µm or 50/125 µm core diameter LC connector on both sides |
Electrical properties
| Electrical isolation | PLC isolated from POWERLINK (X1) |
Operating conditions
| Mounting orientation / Horizontal | Yes |
| Mounting orientation / Vertical | Yes |
| Installation elevation above sea level / 0 to 2000 m | No limitation |
| Installation elevation above sea level / >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature / Operation / Horizontal mounting orientation | -25 to 60°C |
| Temperature / Operation / Vertical mounting orientation | -25 to 50°C |
| Temperature / Derating | - |
| Temperature / Storage | -40 to 85°C |
| Temperature / Transport | -40 to 85°C |
| Relative humidity / Operation | 5 to 95%, non-condensing |
| Relative humidity / Storage | 5 to 95%, non-condensing |
| Relative humidity / Transport | 5 to 95%, non-condensing |
Mechanical properties
| Slot | In the X20 PLC |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
Manuals
3D CAD models
ECAD / EPLAN
Certificates
- 2226379 CSA Certificate of Compliance X20 X67
- CCS Type Approval Certificate - X20
- E115267 UL Certificate of Compliance X20
- EU Data Act - X20 IO - Connected Product Information Notice
- EU Declaration ATEX X20
- EU Declaration of conformity PLC X20
- FTZU 09 ATEX 0083X
- UK Declaration PLC X20
- X20, X67 KC certificates
- X20 Package leaflet ATEX/CSA
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.