IAC

B&R X20IF10A1-1

ASi interface master Electrically isolated 4-pin bus connector The interface module is equipped with an ASi master interface. This allows third-party components to be integrated in the B&R system and makes it possible to quickly and easily transfer data in both directions. The interface module can be operated in the X20 controllers or in the expandable X20BC1083 POWERLINK bus controller.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
Communication moduleASi interface master
General information
Diagnostics / Module statusYes, using LED status indicator and software
Diagnostics / Network statusYes, using LED status indicator and software
Diagnostics / Data transferYes, using LED status indicator
Power consumption / Bus1.1 W
Power consumption / Fieldbus0.85 W
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X
Certifications / ULcULus E115267 Industrial control equipment
Certifications / HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
Certifications / DNVTemperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)
Certifications / CCSYes
Certifications / LRENV1
Certifications / KRYes
Certifications / ABSYes
Certifications / BVEC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck
Certifications / KCYes
B&R ID code0xA718
Status indicatorsModule status, network status, data transfer
Fieldbus current consumptionMax. 27 mA
Additional power dissipation caused by actuators (resistive) [W]-
Interfaces
Interface IF1 / Max. distance / Standard100 m
Interface IF1 / Max. distance / With additional components500 m
Interface IF1 / FieldbusASi interface master
Interface IF1 / TypeASi master profile M4
Interface IF1 / Variant4-pin male multipoint connector
Interface IF1 / Power supplyASi power supply
Interface IF1 / Voltage range24 to 32 V
Interface IF1 / ControllernetX100
Interface IF1 / Max. number of slaves62
Interface IF1 / Max. cycle time5 ms
Interface IF1 / Response timeTyp. 3 ms
Electrical properties
Electrical isolationPLC isolated from AS (IF1)
Operating conditions
Mounting orientation / HorizontalYes
Mounting orientation / VerticalYes
Installation elevation above sea level / 0 to 2000 mNo limitation
Installation elevation above sea level / >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Horizontal mounting orientation-25 to 60°C
Temperature / Operation / Vertical mounting orientation-25 to 50°C
Temperature / Derating-
Temperature / Storage-40 to 85°C
Temperature / Transport-40 to 85°C
Relative humidity / Operation5 to 95%, non-condensing
Relative humidity / Storage5 to 95%, non-condensing
Relative humidity / Transport5 to 95%, non-condensing
Mechanical properties
NoteOrder 1x terminal block TB704 separately.
SlotIn the X20 PLC and expandable bus controller X20BC1083

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.