B&R X20IF10X0
Controller-Controller data synchronization module for controller redundancy system Interface module for redundant operation of controllers.
Lifecycle & replacement
Lifecycle status not indexed
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
Short description
| Communication module | Controller redundancy link module |
General information
| Diagnostics / Module status | Yes, using LED status indicator and software |
| Diagnostics / Bus function | Yes, using LED status indicator and software |
| Diagnostics / Data transfer | Yes, using LED status indicator and software |
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / CRA (Cyber Resilience Act) | In preparation |
| Certifications / ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X |
| Certifications / UL | cULus E115267 Industrial control equipment |
| Certifications / HazLoc | cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
| Certifications / DNV | Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck) |
| Certifications / CCS | Yes |
| Certifications / LR | ENV1 |
| Certifications / KR | Yes |
| Certifications / ABS | Yes |
| Certifications / BV | EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck |
| Certifications / KC | Yes |
| B&R ID code | 0xC3B4 |
| Status indicators | Module status, bus function |
| Power consumption | 1.93 W |
| Additional power dissipation caused by actuators (resistive) [W] | - |
Interfaces
| Transfer / Physical layer | 1000BASE-SX |
| Line length / MMF 50/125 µm | Min.: 2 m, max.: Up to 500 m |
| Line length / MMF 62.5/125 µm | Min.: 2 m, max.: Up to 300 m |
| Fieldbus | Redundancy link |
| Standard (compliance) | IEEE Std 802.3, 2002 edition, clause 38 |
| Execution | 1x duplex LC |
| Transfer rate | 1 Gbit/s |
| Wave length | 850 nm |
| Cable fiber type | Multimode fiber with 62.5/125 µm or 50/125 µm core diameter LC connector on both sides |
Operating conditions
| Mounting orientation / Horizontal | Yes |
| Mounting orientation / Vertical | Yes |
| Installation elevation above sea level / 0 to 2000 m | No limitation |
| Installation elevation above sea level / >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature / Operation / Horizontal mounting orientation | -25 to 60°C |
| Temperature / Operation / Vertical mounting orientation | -25 to 50°C |
| Temperature / Derating | See section "Derating". |
| Temperature / Storage | -40 to 85°C |
| Temperature / Transport | -40 to 85°C |
| Relative humidity / Operation | 5 to 85%, non-condensing |
| Relative humidity / Storage | 5 to 85%, non-condensing |
| Relative humidity / Transport | 5 to 85%, non-condensing |
Mechanical properties
| Slot | Left IF slot of X20CP368x PLC |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
Manuals
3D CAD models
ECAD / EPLAN
Certificates
- 2226379 CSA Certificate of Compliance X20 X67
- 64331_A1 BV Certificate of Compliance X20
- 64331_A1 BV Certificate of Compliance X20(de)
- ABS Certificate of Product Design Assessment - X20 IO Series
- CCS Type Approval Certificate - X20
- E115267 UL Certificate of Compliance X20
- EU Data Act - X20 IO - Connected Product Information Notice
- EU Declaration ATEX X20
- EU Declaration of conformity PLC X20
- FTZU 09 ATEX 0083X
- KR Type Approval Certificate MIL39390-AC003 (X20 System)
- Lloyds Register (X20 only)
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.