IAC

B&R X20PD2113

Integrated exchangeable microfuse Monitoring of the fuse Potential for routing as needed Can be used as feed module for the I/O supply The potential distributor module with feed can provide 6x 24 VDC and 6x ground connections from the internal I/O supply on the terminals. This module can also be used instead of a special feed module for the internal I/O supply. The internal 24 VDC supply is connected to the terminal connections through a replaceable microfuse for protection. The 24 VDC feed and the functionality of the fuse are monitored.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
Potential distributor module with supply6x 24 VDC on the terminals, 6x ground on the terminals
General information
Diagnostics / Module run/errorYes, using LED status indicator and software
Diagnostics / Fuse monitoringYes, using LED status indicator and software
Power consumption / Bus0.12 W
Power consumption / Internal I/O1.15 W
Power consumption / External I/O1.15 W
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X
Certifications / ULcULus E115267 Industrial control equipment
Certifications / HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
Certifications / DNVTemperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)
Certifications / CCSYes
Certifications / LRENV1
Certifications / KRYes
Certifications / ABSYes
Certifications / BVEC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck
Certifications / KCYes
B&R ID code0x267F
Status indicatorsOperating state, module status
Additional power dissipation caused by actuators (resistive) [W]-
Input power supply with feed
Nominal input voltage24 VDC -15% / +20% external, ground external
Input currentMax. 6 A
FuseIntegrated 6.3 A, slow-blow, can be replaced
Behavior on short circuitNo protection available Use an external fuse.
Reverse polarity protectionNo
Output I/O power supply
Behavior on short circuit / On 24 VDC power supplyIntegrated fuse
Behavior on short circuit / On GND power supplyNo protection available
Nominal output voltage24 VDC, ground
Permissible contact load6 A
Operating conditions
Mounting orientation / HorizontalYes
Mounting orientation / VerticalYes
Installation elevation above sea level / 0 to 2000 mNo limitation
Installation elevation above sea level / >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Horizontal mounting orientation-25 to 60°C
Temperature / Operation / Vertical mounting orientation-25 to 50°C
Temperature / Derating-
Temperature / Storage-40 to 85°C
Temperature / Transport-40 to 85°C
Relative humidity / Operation5 to 95%, non-condensing
Relative humidity / Storage5 to 95%, non-condensing
Relative humidity / Transport5 to 95%, non-condensing
Mechanical properties
NoteOrder 1x terminal block X20TB12 separately. Order 1x bus module X20BM01 or X20BM11 separately.
Pitch12.5⁺⁰.² mm