B&R X20SL8000

SafeLOGIC controllers handle all central tasks within a safety-related application. Three different functional areas exist here. The configuration management system monitors the entire safety-related configuration of the application. When replacements are needed, the parameter management system makes sure that newly installed modules are assigned correct parameters that apply to the application. Lastly, SafeLOGIC handles the actual safety-related execution of the application program.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
InterfacesPOWERLINK
System moduleCPU
General information
System requirements / Automation Studio3.0.71 or later
System requirements / Automation Runtime2.95 or later
System requirements / SafeDESIGNER2.58 and later, up to 3.0
System requirements / Safety Release1.1 and later, up to 1.6
Diagnostics / CPU functionYes, using LED status indicator
Diagnostics / POWERLINKYes, using LED status indicator
Diagnostics / SafeKEYYes, using LED status indicator
Certifications / CEYes
Certifications / UKCAYes
Certifications / Functional safetycULus FSPC E361559 Energy and industrial systems Certified for functional safety ANSI UL 1998:2013
Certifications / Functional safety #2IEC 61508:2010, SIL 3 EN 62061:2005/A2:2015, SIL 3 EN ISO 13849-1:2015, Cat. 4 / PL e IEC 61511:2004, SIL 3
Certifications / Functional safety #3EN 50156-1:2004
Certifications / ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X
Certifications / ULcULus E115267 Industrial control equipment
Certifications / HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
Certifications / DNVTemperature: A (0 to 45°C) Humidity: B (up to 100%) Vibration: A (0.7 g) EMC: B (bridge and open deck)
Certifications / CCSYes
Certifications / LRENV1
Certifications / KRYes
Certifications / ABSYes
Certifications / BVEC21B Temperature: 5 - 45°C Vibration: 0.7 g EMC: Bridge and open deck
Certifications / KCYes
CoolingFanless
Status indicatorsCPU function, POWERLINK, SafeKEY
Power consumption5.1 W
Safety characteristics
EN ISO 13849-1:2015 / CategoryCat. 4
EN ISO 13849-1:2015 / PLPL e
EN ISO 13849-1:2015 / DC>94%
EN ISO 13849-1:2015 / MTTFD per channel2500 years
EN ISO 13849-1:2015 / Mission timeMax. 20 years
IEC 61508:2010, IEC 61511:2004, EN 62061:2013 / PFH / PFHd / Module<1*10⁻¹⁰
IEC 61508:2010, IEC 61511:2004, EN 62061:2013 / PFH / PFHd / openSAFETY wiredNegligible
IEC 61508:2010, IEC 61511:2004, EN 62061:2013 / PFH / PFHd / openSAFETY wireless<1*10⁻¹⁴ * Number of openSAFETY packets per hour
IEC 61508:2010, IEC 61511:2004, EN 62061:2013 / SIL CLSIL 3
IEC 61508:2010, IEC 61511:2004, EN 62061:2013 / SFF>90%
IEC 61508:2010, IEC 61511:2004, EN 62061:2013 / PFD per channel<2*10⁻⁵
IEC 61508:2010, IEC 61511:2004, EN 62061:2013 / Proof test interval (PT)20 years
Functionality
Number of supported safety nodesMax. 20
Communication with each otherCommunication only possible with SafeLOGIC controller SL8001 or SL8011
Support for machine optionsNo
SafeMOTION supportNo
Shortest task class cycle time1 ms
Fieldbus
TypePOWERLINK
VariantInternal 2-port hub, 2x RJ45 shielded
Line lengthMax. 100 m between 2 stations (segment length)
Transfer rate100 Mbit/s
Cycle timeMax. 20 ms
Power supply
Nominal voltage24 VDC -15% / +20%
FuseIntegrated, cannot be replaced
Reverse polarity protectionYes
Operating conditions
Mounting orientation / HorizontalYes
Mounting orientation / VerticalYes
Installation elevation above sea level0 to 2000 m, no limitation
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Horizontal mounting orientation0 to 55°C
Temperature / Operation / Vertical mounting orientation0 to 45°C
Temperature / Derating-
Temperature / Storage-25 to 70°C
Temperature / Transport-25 to 70°C
Relative humidity / Operation5 to 95%, non-condensing
Relative humidity / Storage5 to 95%, non-condensing
Relative humidity / Transport5 to 95%, non-condensing
Mechanical properties
Dimensions / Width87.5⁺⁰.² mm
Dimensions / Height99 mm
Dimensions / Depth75 mm
NoteOrder application memory (SafeKEY) separately. X20 end cover plate (right) is included in delivery. 12-pin X20 terminal block, safety-keyed, is included in delivery. SafeKEY cover is included in delivery.
Weight290 g

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.