IAC

B&R X20SL8100

openSAFETY manager for up to 100 SafeNODEs Flexibly programmable using Automation Studio / SafeDESIGNER Innovative management of safe machine options (SafeOPTION) Parameter and configuration management The module is equipped with SafeLOGIC functionality that allows it to safely execute applications designed in SafeDESIGNER. The module can be used in safety-related applications up to PL e or SIL 3. In addition, the module coordinates the safety-related communication of all modules involved in the application. In this context, the module also monitors the configuration of these modules and carries out autonomous parameter downloads to the modules whenever necessary. This guarantees a consistent and correct module configuration in the network from a safety standpoint in all scenarios involving module replacement and service. These services are performed by the SafeLOGIC controller.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
InterfacesPOWERLINK
System moduleCPU
General information
Diagnostics / CPU functionYes, using LED status indicator
Diagnostics / POWERLINKYes, using LED status indicator
Diagnostics / SafeKEYYes, using LED status indicator
Support / Dynamic node allocation (DNA)Yes
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / Functional safetycULus FSPC E361559 Energy and industrial systems Certified for functional safety ANSI UL 1998:2013
Certifications / Functional safety #2IEC 61508, up to SIL 3 IEC 62061, up to SIL 3 ISO 13849-1, up to Cat. 4 / PL e IEC 61511, up to SIL 3
Certifications / Functional safety #3EN 50156-1
Certifications / ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X
Certifications / ULcULus E115267 Industrial control equipment cULus E537419 Engine generator controller
Certifications / HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
Certifications / DNVTemperature: A (0 to 45°C) Humidity: B (up to 100%) Vibration: A (0.7 g) EMC: B (bridge and open deck)
Certifications / CCSYes
Certifications / LRENV1
Certifications / KRYes
Certifications / ABSYes
Certifications / BVEC21B Temperature: 5 - 45°C Vibration: 0.7 g EMC: Bridge and open deck
B&R ID code0xDD61
CoolingFanless
Status indicatorsCPU function, POWERLINK, SafeKEY
Power consumption4.3 W
Additional power dissipation caused by actuators (resistive) [W]-
Safety characteristics
NoteSee section "Safety characteristics".
Limit values for SafeDESIGNER application
Max. resources available for SafeDESIGNER info window entries / FB instances4096
Max. resources available for SafeDESIGNER info window entries / Marker memory262,144 bytes
Max. resources available for SafeDESIGNER info window entries / Stack memory32,768 bytes
Max. resources available for SafeDESIGNER info window entries / Memory for safe input data6144 bytes
Max. resources available for SafeDESIGNER info window entries / Memory for safe output data2048 bytes
Max. resources available for SafeDESIGNER info window entries / Memory for standard input data1024 bytes
Max. resources available for SafeDESIGNER info window entries / Memory for standard output data1024 bytes
Max. resources available for SafeDESIGNER info window entries / Marker count16,382
Additional SafeDESIGNER limit values / Max. number of function block types512
Additional SafeDESIGNER limit values / Max. number of force variables64
Additional SafeDESIGNER limit values / Max. number of variable with variable status1023
Input SL / BC / X2X Link power supply
Input voltage24 VDC -15% / +20%
Input currentMax. 0.25 A
Fuse-
Reverse polarity protectionYes
Interfaces
Transfer / Physical layer100BASE-TX
Transfer / Half-duplexYes
Transfer / Full-duplexNo
Transfer / AutonegotiationYes
Transfer / Auto-MDI/MDIXYes
Min. cycle time / Fieldbus200 µs
FieldbusPOWERLINK controlled node
Variant2x shielded RJ45 port (hub)
Line lengthMax. 100 m between 2 nodes (segment length)
Transfer rate100 Mbit/s
Operating conditions
Mounting orientation / HorizontalYes
Mounting orientation / VerticalYes
Installation elevation above sea level0 to 2000 m, no limitation
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Horizontal mounting orientation0 to 60°C
Temperature / Operation / Vertical mounting orientation0 to 45°C
Temperature / Derating-
Temperature / Storage-40 to 85°C
Temperature / Transport-40 to 85°C
Relative humidity / Operation5 to 95%, non-condensing
Relative humidity / Storage5 to 95%, non-condensing
Relative humidity / Transport5 to 95%, non-condensing
Mechanical properties
Dimensions / Width62.5⁺⁰.² mm
Dimensions / Height99 mm
Dimensions / Depth75 mm
NoteOrder SafeKEY and SafeLOGIC range of functions using the X20MK configurator. X20 end cover plate (right) included in delivery 12-pin X20 terminal block, safety-keyed, included in delivery SafeKEY cover included in delivery
Weight190 g

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.