IAC

B&R X20SL8201

X20 SafeLOGIC controller, Gen.3 (Safety+) openSAFETY gateway, 1 POWERLINK interface, controlled node, integrated 2-port hub, with X20 bus controller, including power supply module for internal I/O power supply and X2X power supply, 1x terminal block X20TB52 and X20 end cover plate (right) X20AC0SR1 included

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
InterfacesPOWERLINK
System moduleCPU
General information
Diagnostics / CPU functionYes, using LED status indicator
Diagnostics / POWERLINKYes, using LED status indicator
Support / Dynamic node allocation (DNA)Yes
Power consumption / Internal I/O0.6 W
Electrical isolation / Fieldbus - X2X LinkYes
Electrical isolation / Fieldbus - I/OYes
Certifications / CEYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / Functional safetyIEC 61508 in preparation EN 62061 in preparation EN ISO 13849-1 in preparation IEC 61511 in preparation
B&R ID code0x2C9C
CoolingFanless
Status indicatorsCPU function, POWERLINK
Power consumption4 W
Power consumption for X2X Link power supply1.42 W
Additional power dissipation caused by actuators (resistive) [W]-
Safety characteristics
NoteSee section "Safety characteristics".
Input SL / BC / X2X Link power supply
Input voltage24 VDC -15% / +20%
Input currentMax. 0.9 A
FuseIntegrated, cannot be replaced
Reverse polarity protectionNo
Output SL / BC / X2X Link power supply
Nominal output power7 W
Parallel connectionYes
Redundant operationYes
Overload characteristicsShort-circuit proof, temporary overload
Input I/O power supply
Input voltage24 VDC -15% / +20%
FuseRequired line fuse: Max. 10 A slow-blow
Reverse polarity protectionNo
Output I/O power supply
Nominal output voltage24 VDC
Behavior on short circuitRequired line fuse
Permissible contact load10 A
Interfaces
Transfer / Physical layer100BASE-TX
Transfer / Half-duplexYes
Transfer / Full-duplexNo
Transfer / AutonegotiationYes
Transfer / Auto-MDI/MDIXYes
Min. cycle time / Fieldbus200 µs
Min. cycle time / X2X Link200 µs
FieldbusPOWERLINK controlled node
Variant2x shielded RJ45 port (hub)
Line lengthMax. 100 m between 2 nodes (segment length)
Transfer rate100 Mbit/s
Synchronization between bus systems possibleYes
Operating conditions
Mounting orientation / HorizontalYes
Mounting orientation / VerticalYes
Installation elevation above sea level0 to 2000 m: No limitation 2000 to 4000 m: Reduction of the ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Horizontal mounting orientation0 to 60°C
Temperature / Operation / Vertical mounting orientation0 to 50°C
Temperature / DeratingSee section "Derating".
Temperature / Storage-40 to 85°C
Temperature / Transport-40 to 85°C
Relative humidity / Operation5 to 95%, non-condensing
Relative humidity / Storage5 to 95%, non-condensing
Relative humidity / Transport5 to 95%, non-condensing
Mechanical properties
Dimensions / Width62.5⁺⁰.² mm
Dimensions / Height99 mm
Dimensions / Depth75 mm
NoteX20 end cover plate (right) included in delivery 12-pin X20 terminal block, safety-keyed, included in delivery
Weight198 g

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.