IAC

B&R X20SLX806

openSAFETY manager for up to 10 SafeNODEs Flexibly programmable using Automation Studio / SafeDESIGNER Innovative management of safe machine options (SafeOPTION) Parameter and configuration management 8 safe digital inputs, sink circuit 4 pulse outputs Software input filter configurable for each channel 6 safe digital outputs, output type B with 0.2 A, source circuit Integrated output protection The module is equipped with SafeLOGIC functionality that allows it to safely execute applications designed in SafeDESIGNER. The module can be used in safety-related applications up to PL e or SIL 3. In addition, the module coordinates the safety-related communication of all modules involved in the application. In this context, the module also monitors the configuration of these modules and carries out autonomous parameter downloads to the modules whenever necessary. This guarantees a consistent and correct module configuration in the network from a safety standpoint in all scenarios involving module replacement and service. These services are performed in conjunction with Automation Runtime on the standard CPU. In addition, SafeLOGIC-X products have the same I/O properties as the associated SafeIO products (X20SC0xxx).

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
I/O module8 safe type A digital inputs, 4 pulse outputs, 24 VDC, 6 safe type B2 digital outputs, 24 VDC, 0.2 A, OSSD <10 µs, SafeLOGIC-X technology
General information
Diagnostics / Module run/errorYes, using LED status indicator and software
Diagnostics / OutputsYes, using LED status indicator and software
Diagnostics / InputsYes, using LED status indicator and software
Blackout mode / ScopeModule
Blackout mode / FunctionProgrammable
Blackout mode / Standalone modeYes
Power consumption / Bus0.4 W
Power consumption / Internal I/O2.5 W
Additional power dissipation caused by actuators (resistive) [W] / Safe digital HS-HS outputs1.2
Additional power dissipation caused by actuators (resistive) [W] / Pulse outputs0.8
Electrical isolation / Channel - BusYes
Electrical isolation / Channel - ChannelNo
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / Functional safetycULus FSPC E361559 Energy and industrial systems Certified for functional safety ANSI UL 1998:2013
Certifications / Functional safety #2IEC 61508, up to SIL 3 IEC 62061, up to SIL 3 ISO 13849-1, up to Cat. 4 / PL e IEC 61511, up to SIL 3
Certifications / Functional safety #3EN 50156-1
Certifications / ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X
Certifications / ULcULus E115267 Industrial control equipment cULus E537419 Engine generator controller
B&R ID code0xE758
Status indicatorsI/O function per channel, operating state, module status
Safety characteristics
NoteSee section "Safety characteristics".
Limit values for SafeDESIGNER application
Max. resources available for SafeDESIGNER info window entries / FB instances256
Max. resources available for SafeDESIGNER info window entries / Marker memory5120 bytes (0x1400)
Max. resources available for SafeDESIGNER info window entries / Stack memory4096 bytes
Max. resources available for SafeDESIGNER info window entries / Memory for safe input data128 bytes, 68 bytes of which are usable for modules
Max. resources available for SafeDESIGNER info window entries / Memory for safe output data64 bytes
Max. resources available for SafeDESIGNER info window entries / Memory for standard input data64 bytes
Max. resources available for SafeDESIGNER info window entries / Memory for standard output data64 bytes
Max. resources available for SafeDESIGNER info window entries / Marker count256
Additional SafeDESIGNER limit values / Max. number of function block types64
Additional SafeDESIGNER limit values / Max. number of force variables8
Additional SafeDESIGNER limit values / Max. number of variable with variable status128
I/O power supply
Nominal voltage24 VDC
Voltage range24 VDC -15% / +20%
Integrated protective functionReverse polarity protection
Safe digital inputs
Input filter / Hardware≤150 µs
Input filter / SoftwareConfigurable between 0 and 500 ms
Switching threshold / Low<5 VDC
Switching threshold / High>15 VDC
Quantity8
VariantType A
Nominal voltage24 VDC
Input characteristics per EN 61131-2Type 1
Input circuitSink
Input voltage24 VDC -15% / +20%
Input current at 24 VDCMin. 2 mA to max. 3.28 mA
Input resistanceMin. 7.33 kΩ
Error detection time100 ms
Insulation voltage between channel and bus500 Veff
Line length between signal source (pulse output or external signal) and inputMax. 60 m with unshielded line Max. 400 m with shielded line
Safe digital HS-HS outputs
Quantity6
VariantFET, 2x positive switching, type B2, output level readable
Nominal voltage24 VDC
Nominal output current0.2 A
Total nominal current1.2 A
Output protectionSee section "Inrush current behavior for output channels".
Braking voltage when switching off inductive loadsMax. 45 VDC
Error detection time1 s
Insulation voltage between channel and bus500 Veff
Peak short-circuit currentSee section "Inrush current behavior for output channels".
Leakage current when the output is switched off<100 µA
RDS(on)5 Ω
Switching voltageI/O power supply minus voltage drop due to RDS(on)
Max. switching frequencySee section "Inrush current behavior for output channels".
Test pulse lengthMax. 10 µs
Max. capacitive load100 nF
Current on loss of ground
IOUT<100 µA
IGND<200 mA
Pulse outputs
Quantity4
VariantPush-Pull
Nominal output current50 mA
Output protectionShutdown of individual channels in the event of overload or short circuit
Peak short-circuit current0.5 A for 120 µs
Short-circuit current15 mAeff
Leakage current when the output is switched off0.1 mA
RDS(on)80 Ω
Switching voltageI/O power supply minus voltage drop due to RDS(on)
Total nominal current200 mA
Operating conditions
Mounting orientation / HorizontalYes
Mounting orientation / VerticalYes
Installation elevation above sea level0 to 2000 m, no limitation
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Horizontal mounting orientation0 to 60°C
Temperature / Operation / Vertical mounting orientation0 to 50°C
Temperature / DeratingSee section "Derating".
Temperature / Storage-40 to 85°C
Temperature / Transport-40 to 85°C
Relative humidity / Operation5 to 95%, non-condensing
Relative humidity / Storage5 to 95%, non-condensing
Relative humidity / Transport5 to 95%, non-condensing
Mechanical properties
NoteOrder 2x safety-keyed terminal block separately. Order 1x safety-keyed bus module separately.
Pitch25⁺⁰.² mm

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.