B&R X20SLX811-1
X20 SafeLOGIC-X controller (Safety+) 8 safe type A digital inputs, 4 pulse outputs, 24 VDC
Lifecycle & replacement
Lifecycle status not indexed
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
Short description
| I/O module | 8 safe type A digital inputs, 4 pulse outputs, 24 VDC, SafeLOGIC-X technology |
General information
| Diagnostics / Module run/error | Yes, using LED status indicator and software |
| Diagnostics / Inputs | Yes, using LED status indicator and software |
| Power consumption / Bus | 0.4 W |
| Power consumption / Internal I/O | 2.5 W |
| Additional power dissipation caused by actuators (resistive) [W] / Pulse outputs | 0.8 |
| Electrical isolation / Channel - Bus | Yes |
| Electrical isolation / Channel - Channel | No |
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / CRA (Cyber Resilience Act) | In preparation |
| Certifications / Functional safety | IEC 61508:2010, SIL 3 EN 62061:2005/A2:2015, SIL 3 EN ISO 13849-1:2015, Cat. 4 / PL e IEC 61511:2004, SIL 3 |
| Certifications / Functional safety #2 | EN 50156-1:2004 |
| Certifications / ATEX | In preparation |
| Certifications / UL | cULus E115267 Industrial control equipment cULus E537419 Engine generator controller |
| B&R ID code | 0x2F21 |
| Status indicators | I/O function per channel, operating state, module status |
Safety characteristics
| Note | See section "Safety characteristics". |
Safe digital inputs
| Input filter / Hardware | ≤150 µs |
| Input filter / Software | Configurable between 0 and 500 ms |
| Switching threshold / Low | <5 VDC |
| Switching threshold / High | >15 VDC |
| Quantity | 8 |
| Variant | Type A |
| Nominal voltage | 24 VDC |
| Input characteristics per EN 61131-2 | Type 1 |
| Input circuit | Sink |
| Input voltage | 24 VDC -15% / +20% |
| Input current at 24 VDC | Min. 2 mA to max. 3.28 mA |
| Input resistance | Min. 7.33 kΩ |
| Error detection time | 100 ms |
| Insulation voltage between channel and bus | 500 Veff |
| Line length between signal source (pulse output or external signal) and input | Max. 60 m with unshielded line Max. 400 m with shielded line |
Pulse outputs
| Quantity | 4 |
| Variant | Push-Pull |
| Nominal output current | 50 mA |
| Output protection | Shutdown of individual channels in the event of overload or short circuit |
| Peak short-circuit current | 0.5 A for 120 µs |
| Short-circuit current | 15 mAeff |
| Leakage current when the output is switched off | 0.1 mA |
| RDS(on) | 80 Ω |
| Switching voltage | I/O power supply minus voltage drop due to RDS(on) |
| Total nominal current | 200 mA |
Operating conditions
| Mounting orientation / Horizontal | Yes |
| Mounting orientation / Vertical | Yes |
| Installation elevation above sea level | 0 to 2000 m, no limitation |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature / Operation / Horizontal mounting orientation | 0 to 60°C |
| Temperature / Operation / Vertical mounting orientation | 0 to 50°C |
| Temperature / Derating | See section "Derating". |
| Temperature / Storage | -40 to 85°C |
| Temperature / Transport | -40 to 85°C |
| Relative humidity / Operation | 5 to 95%, non-condensing |
| Relative humidity / Storage | 5 to 95%, non-condensing |
| Relative humidity / Transport | 5 to 95%, non-condensing |
Mechanical properties
| Note | Order 1x safety-keyed terminal block separately. Order 1x safety-keyed bus module (single-width) separately. |
| Pitch | 12.5⁺⁰.² mm |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
Manuals
ECAD / EPLAN
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.