B&R X20SLX842-1
X20 SafeLOGIC-X controller (Safety+) 8 safe type A digital inputs, 4 pulse outputs, 24 VDC, 4 safe type A digital outputs, 24 VDC, 3 A, OSSD <500 µs, 2 safe type B digital outputs, 24 VDC, 50 mA, OSSD <500 µs
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
Short description
| I/O module | 8 safe type A digital inputs, 4 pulse outputs, 24 VDC, 4 safe type A digital outputs, 24 VDC, 3 A, OSSD <500 µs, 2 safe type B2 digital outputs, 24 VDC, 50 mA, OSSD <500 µs, SafeLOGIC-X technology |
General information
| Diagnostics / Module run/error | Yes, using LED status indicator and software |
| Diagnostics / Outputs | Yes, using LED status indicator and software |
| Diagnostics / Inputs | Yes, using LED status indicator and software |
| Blackout mode / Scope | Module |
| Blackout mode / Function | Programmable |
| Blackout mode / Standalone mode | Yes |
| Power consumption / Bus | 0.4 W |
| Power consumption / Internal I/O | 2.5 W |
| Additional power dissipation caused by actuators (resistive) [W] / Safe digital HS-LS outputs | 0.84 |
| Additional power dissipation caused by actuators (resistive) [W] / Safe digital HS-HS outputs | 0.175 |
| Additional power dissipation caused by actuators (resistive) [W] / Pulse outputs | 0.8 |
| Electrical isolation / Channel - Bus | Yes |
| Electrical isolation / Channel - Channel | No |
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / CRA (Cyber Resilience Act) | In preparation |
| Certifications / Functional safety | IEC 61508, up to SIL 3 IEC 62061, up to SIL 3 ISO 13849-1, up to Cat. 4 / PL e IEC 61511, up to SIL 3 |
| Certifications / Functional safety #2 | EN 50156-1 |
| Certifications / ATEX | In preparation |
| Certifications / UL | cULus E115267 Industrial control equipment cULus E537419 Engine generator controller |
| B&R ID code | 0x2F20 |
| Status indicators | I/O function per channel, operating state, module status |
Safety characteristics
| Note | See section "Safety characteristics". |
Safe digital inputs
| Input filter / Hardware | ≤150 µs |
| Input filter / Software | Configurable between 0 and 500 ms |
| Switching threshold / Low | <5 VDC |
| Switching threshold / High | >15 VDC |
| Quantity | 8 |
| Variant | Type A |
| Nominal voltage | 24 VDC |
| Input characteristics per EN 61131-2 | Type 1 |
| Input circuit | Sink |
| Input voltage | 24 VDC -15% / +20% |
| Input current at 24 VDC | Min. 2 mA to max. 3.28 mA |
| Input resistance | Min. 7.33 kΩ |
| Error detection time | 100 ms |
| Insulation voltage between channel and bus | 500 Veff |
| Line length between signal source (pulse output or external signal) and input | Max. 60 m with unshielded line Max. 400 m with shielded line |
Safe digital HS-LS outputs
| Quantity | 4 |
| Variant | FET, 1x positive switching, 1x negative switching, type A, output level readable |
| Nominal voltage | 24 VDC |
| Nominal output current | 3 A |
| Total nominal current | 10 A |
| Output protection | See section "Inrush current behavior for output channels". |
| Braking voltage when switching off inductive loads | Max. 90 VDC |
| Error detection | 1 s |
| Insulation voltage between channel and bus | 500 Veff |
| Peak short-circuit current | See section "Inrush current behavior for output channels". |
| Leakage current when the output is switched off | <1 mA |
| RDS(on) | 30 mΩ |
| Switching voltage | I/O power supply minus voltage drop due to RDS(on) |
| Max. switching frequency | See section "Inrush current behavior for output channels". |
| Test pulse length | Max. 500 µs |
| Max. capacitive load | 100 nF |
Safe digital HS-HS outputs
| Quantity | 2 |
| Variant | FET, 2x positive switching, type B2, output level readable |
| Nominal voltage | 24 VDC |
| Nominal output current | 50 mA |
| Total nominal current | 100 mA |
| Output protection | See section "Inrush current behavior for output channels". |
| Braking voltage when switching off inductive loads | Max. 45 VDC |
| Error detection time | 1 s |
| Insulation voltage between channel and bus | 500 Veff |
| Peak short-circuit current | See section "Inrush current behavior for output channels". |
| Leakage current when the output is switched off | <1 mA |
| RDS(on) | 35 Ω |
| Switching voltage | I/O power supply minus voltage drop due to RDS(on) |
| Max. switching frequency | See section "Inrush current behavior for output channels". |
| Test pulse length | Max. 500 µs |
| Max. capacitive load | 100 nF |
Current on loss of ground
| IOUT | <100 µA |
| IGND | <50 mA |
Pulse outputs
| Quantity | 4 |
| Variant | Push-Pull |
| Nominal output current | 50 mA |
| Output protection | Shutdown of individual channels in the event of overload or short circuit |
| Peak short-circuit current | 0.5 A for 120 µs |
| Short-circuit current | 15 mAeff |
| Leakage current when the output is switched off | 0.1 mA |
| RDS(on) | 80 Ω |
| Switching voltage | I/O power supply minus voltage drop due to RDS(on) |
| Total nominal current | 200 mA |
Operating conditions
| Mounting orientation / Horizontal | Yes |
| Mounting orientation / Vertical | Yes |
| Installation elevation above sea level | 0 to 2000 m, no limitation |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature / Operation / Horizontal mounting orientation | 0 to 60°C |
| Temperature / Operation / Vertical mounting orientation | 0 to 50°C |
| Temperature / Derating | See section "Derating". |
| Temperature / Storage | -40 to 85°C |
| Temperature / Transport | -40 to 85°C |
| Relative humidity / Operation | 5 to 95%, non-condensing |
| Relative humidity / Storage | 5 to 95%, non-condensing |
| Relative humidity / Transport | 5 to 95%, non-condensing |
Mechanical properties
| Note | Order 2x safety-keyed terminal block separately. Order 1x safety-keyed bus module separately. |
| Pitch | 25⁺⁰.² mm |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
Manuals
ECAD / EPLAN
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.