IAC

B&R X20SM1444-1

1 stepper motor, 24 to 48 VDC ±25%, 5 A (10 A peak) Resolution of current values at 1% Boost, nominal and holding current separately configurable Sensorless, load-dependent current control Integrated motor detection 256 microsteps per step Stall detection Complete integration in Automation Studio and CNC applications R+ and R- also configurable as digital inputs Open circuit detection with 5 V differential ABR interface Input ramp limit at max. 12.5 A Function model "Ramp" based on CANopen communication profile DS402 The stepper motor module is used to control stepper motors with a nominal voltage of 24 to 48 VDC (±25%) at a motor current up to 5 A (10 A peak). ABR outputs R+ and R- can also be used as digital inputs. Due to the individual adjustment of the coil currents, the motor is only operated with the current it actually needs. This simplifies the selection of the available motors and prevents unnecessary heating. Because this affects energy consumption and thermal load, the effects are positive on the service life of the complete system. Complete flexibility is achieved through the use of independently adjustable holding, maximum and nominal current values. The current for microsteps is automatically adjusted to the configured current values. In addition, the module contains a sensorless, load-dependent current control. Depending on the operating situation and load, the module regulates the current downwards. Energy savings up to 75% are possible in this way. The automatic motor identification system is an enormous help during standstills. The stepper motor modules can identify the connected motors using their coil characteristics and generate feedback in the form of an analog value. This makes it possible to detect not only wiring errors, but also incorrect motor types being used mistakenly. "Stall detection" is integrated to analyze the motor load. Detection of the stall is defined via a configurable threshold. This allows an overload or motor standstill to be detected precisely in many different types of applications.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
I/O module1 full bridge for controlling stepper motors
General information
Diagnostics / Module run/errorYes, using LED status indicator and software
Diagnostics / OutputYes, using LED status indicator and software
Diagnostics / I/O power supplyYes, using software
Power consumption / Bus0.1 W
Power consumption / Internal I/O-
Power consumption / External I/OAt 18 VDC 0.54 W At 24 VDC 0.6 W At 40 VDC 0.76 W At 60 VDC 0.97 W
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
B&R ID code0xF3ED
Status indicatorsI/O function per channel, operating state, module status
Additional power dissipation caused by actuators (resistive) [W]At 1 A 0.31 W At 2 A 0.574 W At 3 A 0.848 W At 4 A 1.1 W At 5 A 1.4 W
Input current limitingMax. 12.5 A
Type of signal linesShielded lines must be used for all signal lines.
Motor output stage
Module power supply / SupplyExternal
Module power supply / FuseRequired line fuse: Max. 10 A, slow-blow
Quantity1
Type2-phase bipolar stepper motor (full bridge)
Nominal voltage24 to 48 VDC ±25%
Nominal current5 A
Maximum current10 A for 1 s
DC bus capacitance300 µF
Step resolutionMax. 256 microsteps per step
Output protectionReverse polarity protection on supply voltage
Digital inputs
Input filter / Hardware<5 µs
Input filter / Software-
Switching threshold / Low<7.5 VDC
Switching threshold / High>11.5 VDC
Quantity2
Nominal voltage24 VDC
Input circuitSink
Connection type1-wire connections
Input resistanceTyp. 8.2 kΩ
Additional functionsUse as R+ and R- for ABR interface, quick stop and enable function
Open-circuit and short-circuit detectionNo
ABR incremental encoder
Quantity1
Encoder inputs5 V, symmetrical
Counter size16-bit
Input frequencyMax. 125 kHz
Evaluation4x
Open-circuit detectionYes, differential detection
Electrical properties
Electrical isolationChannel isolated from bus and channel isolated from I/O power supply
Operating conditions
Mounting orientation / HorizontalYes
Mounting orientation / VerticalYes
Installation elevation above sea level / 0 to 2000 mNo limitation
Installation elevation above sea level / >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Horizontal mounting orientation-20 to +50°C
Temperature / Operation / Vertical mounting orientation-20 to +40°C
Temperature / DeratingSee section "Derating".
Temperature / Storage-25 to +80°C
Temperature / Transport-25 to +80°C
Relative humidity / Operation5 to 95%, non-condensing
Relative humidity / Storage5 to 95%, non-condensing
Relative humidity / Transport5 to 95%, non-condensing
Mechanical properties
NoteOrder 1x terminal block X20TB12 separately. Order 1x bus module X20BM31 separately.
Pitch25⁺⁰.² mm

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.