IAC

B&R X67AI2744

2 full-bridge strain gauge inputs Data output rate configurable from 2.5 Hz to 7.5 kHz The module is equipped with 2 inputs for evaluating full-bridge strain gauges and works with both 4-wire and 6-wire strain gauge load cells. The concept applied by the module requires calibration in the measurement system. This calibration compensates or eliminates the absolute inaccuracies in the measurement circuit (e.g. component tolerances, effective bridge voltage or zero offset). The measuring accuracy related to an absolute (calibrated) value only changes due to the negative influence of a change in the operating temperature.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
I/O module2 full-bridge strain gauge inputs
General information
Diagnostics / Module run/errorYes, using LED status indicator and software
Diagnostics / Open circuitYes, using LED status indicator and software
Diagnostics / InputYes, using LED status indicator and software
Connection type / X2X LinkM12, B-coded
Connection type / Inputs4x M12, A-coded
Connection type / I/O power supplyM8, 4-pin
Power consumption / Bus0.75 W
Power consumption / Internal I/O2.4 W
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / ATEXZone 2, II 3G Ex nA IIA T5 Gc IP67, Ta = 0 - Max. 60°C TÜV 05 ATEX 7201X
Certifications / ULcULus E115267 Industrial control equipment
Certifications / HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
Certifications / KCYes
B&R ID code0x8820
Status indicatorsChannel status, operating state, module status
I/O power supply
Nominal voltage24 VDC
Voltage range18 to 30 VDC
Integrated protective functionReverse polarity protection
Full-bridge strain gauge
Input filter / Cutoff frequency5 kHz
Input filter / Order3
Input filter / Slope60 dB
Output of digital value / Broken bridge supply lineValue approaching 0
Output of digital value / Broken sensor lineValue approaching ±end value (status bit "Line monitoring" is set in register "Module status")
Output of digital value / Valid range of values0xFF800001 to 0x007FFFFF (-8,388,607 to 8,388,607)
Strain gauge supply / Voltage5.5 VDC / Max. 65 mA
Strain gauge supply / Short-circuit and overload-proofYes
Strain gauge supply / Voltage drop for short-circuit protectionMax. 0.2 VDC at 65 mA and 25°C
Quantization / LSB value (16-bit) / 2 mV/V336 nV
Quantization / LSB value (16-bit) / 4 mV/V671 nV
Quantization / LSB value (16-bit) / 8 mV/V1.343 µV
Quantization / LSB value (16-bit) / 16 mV/V2.686 µV
Quantization / LSB value (16-bit) / 32 mV/V5.371 µV
Quantization / LSB value (16-bit) / 64 mV/V10.74 µV
Quantization / LSB value (16-bit) / 128 mV/V21.48 µV
Quantization / LSB value (16-bit) / 256 mV/V42.97 µV
Quantization / LSB value (24-bit) / 2 mV/V1.31 nV
Quantization / LSB value (24-bit) / 4 mV/V2.62 nV
Quantization / LSB value (24-bit) / 8 mV/V5.25 nV
Quantization / LSB value (24-bit) / 16 mV/V10.49 nV
Quantization / LSB value (24-bit) / 32 mV/V20.98 nV
Quantization / LSB value (24-bit) / 64 mV/V41.96 nV
Quantization / LSB value (24-bit) / 128 mV/V83.92 nV
Quantization / LSB value (24-bit) / 256 mV/V167.85 nV
Strain gauge factor2 to 256 mV/V, configurable using software
Connection4- or 6-wire connections
Input typeDifferential, used to evaluate a full-bridge strain gauge
Digital converter resolution24-bit
Conversion timeDepends on the configured data output rate
Data output rate2.5 to 7,500 samples per second, configurable using software (fDATA)
ADC filter characteristicsSigma-delta, see section "Filter characteristics of the sigma-delta A/D converter"
Operating range / Measurement sensor85 to 5,000 Ω
Influence of cable lengthSee section "Calculation example", sensor cable length: Max. 30 m
Input protectionRC protection
Common-mode range0 to 3 VDC Permissible input voltage range (with regard to the electric potential strain gauge GND) on inputs "Input +" and "Input -"
Insulation voltage between input and bus500 Veff
Conversion procedureSigma-delta
Max. gain drift12 ppm/°C
Max. offset drift2 ppm/°C
Nonlinearity<10 ppm
Electrical properties
Electrical isolationBus isolated from analog input and strain gauge supply voltage Channel not isolated from I/O power supply
Operating conditions
Mounting orientation / HorizontalYes
Mounting orientation / VerticalYes
Installation elevation above sea level / 0 to 2000 mNo limitation
Installation elevation above sea level / >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP67
Ambient conditions
Temperature / Operation-25 to 60°C
Temperature / Derating-
Temperature / Storage-40 to 85°C
Temperature / Transport-40 to 85°C
Mechanical properties
Dimensions / Width53 mm
Dimensions / Height85 mm
Dimensions / Depth42 mm
Torque for connections / M8Max. 0.4 Nm
Torque for connections / M12Max. 0.6 Nm
Weight190 g

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.