IAC

B&R X67AI4850

4 inputs for potentiometer displacement gauge The module is a 4-channel analog input module. It is used to evaluate potentiometer displacement gauges.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
I/O module4 inputs for potentiometer displacement gauge
General information
Diagnostics / Module run/errorYes, using LED status indicator and software
Diagnostics / InputYes, using LED status indicator and software
Connection type / X2X LinkM12, B-coded
Connection type / Inputs4x M12, A-coded
Connection type / I/O power supplyM8, 4-pin
Power consumption / Bus0.75 W
Power consumption / Internal I/O2 W
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / ATEXZone 2, II 3G Ex nA IIA T5 Gc IP67, Ta = 0 - Max. 60°C TÜV 05 ATEX 7201X
Certifications / ULcULus E115267 Industrial control equipment
Certifications / HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
Certifications / KCYes
B&R ID code0x9957
Status indicatorsChannel status, operating state, module status
I/O power supply
Nominal voltage24 VDC
Voltage range18 to 30 VDC
Integrated protective functionReverse polarity protection
Potentiometer power supply
Short-circuit proofYes
Potentiometer supply voltage Upot4.5 V / Max. 50 mA
Voltage drop for short-circuit protection at 50 mAMax. 0.13 VDC
Potentiometer, displacement gauge
Output of digital value / Open circuit on GND0x7FFF
Output of digital value / Open circuit on slider0x7FFF
Output of digital value / Open circuit on Upot0x0000
Output of digital value / Valid range of values0x0000 - 0x7FFF
Input filter / Cutoff frequency10 kHz
Input filter / Slope60 dB/Dec.
Input typeSingle-ended input in the range of 0 to Upot
Digital converter resolution15-bit
Measurement sensor0.5 to 10 kΩ, potentiometer
Conversion time<200 µs for all channels
Output formatINT (16-bit 2s complement)
Short-circuit protection UpotYes
Influence of cable lengthTwisted and shielded conductors, cable length as short as possible, cable routing separate from load circuits, without intermediate terminal to sensor
Common-mode range0 to Upot
Insulation voltage between input and bus500 Veff
Quantization; LSB value (14-bit)275 µV
Conversion procedureSample & Hold
Electrical properties
Electrical isolationBus isolated from analog input
Operating conditions
Mounting orientation / HorizontalYes
Mounting orientation / VerticalYes
Installation elevation above sea level / 0 to 2000 mNo limitation
Installation elevation above sea level / >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP67
Ambient conditions
Temperature / Operation-25 to 60°C
Temperature / Derating-
Temperature / Storage-40 to 85°C
Temperature / Transport-40 to 85°C
Mechanical properties
Dimensions / Width53 mm
Dimensions / Height85 mm
Dimensions / Depth42 mm
Torque for connections / M8Max. 0.4 Nm
Torque for connections / M12Max. 0.6 Nm
Weight195 g

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.