B&R X67AT1322
4 inputs for resistance temperature measurement PT100, PT1000 and other resistance temperature sensors Direct resistance measurement Configurable sensor type per channel 2-wire and 4-wire measurement The module is a temperature module for KTY10, KTY84, Pt100 and Pt1000 resistance temperature sensors. The sensors can be connected with 2-wire or 4-wire connections. The sensor type can be set selectively for each input.
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
Short description
| I/O module | 4 inputs for KTY10-6, KTY84-130, Pt100 or Pt1000 resistance temperature measurement |
General information
| Diagnostics / Inputs | Yes, using LED status indicator and software |
| Diagnostics / I/O power supply | Yes, using LED status indicator and software |
| Connection type / X2X Link | M12, B-coded |
| Connection type / Inputs | 4x M12, A-coded |
| Connection type / I/O power supply | M8, 4-pin |
| Power consumption / Internal I/O | 1.5 W |
| Power consumption / X2X Link power supply | 0.75 W |
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / CRA (Cyber Resilience Act) | In preparation |
| Certifications / ATEX | Zone 2, II 3G Ex nA IIA T5 Gc IP67, Ta = 0 - Max. 60°C TÜV 05 ATEX 7201X |
| Certifications / UL | cULus E115267 Industrial control equipment |
| Certifications / HazLoc | cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
| Certifications / KC | Yes |
| B&R ID code | 0x1488 |
| Status indicators | I/O function per channel, supply voltage, bus function |
I/O power supply
| Nominal voltage | 24 VDC |
| Voltage range | 18 to 30 VDC |
| Integrated protective function | Reverse polarity protection |
Resistance measurement temperature inputs
| Conversion time / Same sensor types | 75 ms per channel with 50 Hz filter |
| Conversion time / When switching sensor type | 195 ms per channel with 50 Hz filter |
| Sensor / Sensor type | Configurable per channel |
| Sensor / KTY10-6 | -50 to 145°C |
| Sensor / KTY84-130 | -40 to 300°C |
| Sensor / Pt100 | -200 to 850°C |
| Sensor / Pt1000 | -200 to 850°C |
| Max. error at 25°C / Gain | 0.01% |
| Max. error at 25°C / Offset | 0.015% |
| Temperature sensor resolution / KTY10-6 | 1 LSB = 0.1°C |
| Temperature sensor resolution / KTY84-130 | 1 LSB = 0.1°C |
| Temperature sensor resolution / Pt100 | 1 LSB = 0.1°C |
| Temperature sensor resolution / Pt1000 | 1 LSB = 0.1°C |
| Resistance measurement resolution / G = 1 | 1 LSB = Typ. 69.1223 mΩ ±0.1% |
| Resistance measurement resolution / G = 2 | 1 LSB = Typ. 34.5611 mΩ ±0.1% |
| Input filter / Cutoff frequency | 115 Hz / First-order filter |
| Input filter / Slope | -20 dB |
| Common-mode rejection / 50 Hz | >70 dB |
| Common-mode rejection / DC | >70 dB |
| Temperature measurement monitoring / Range undershoot | 0x8001 |
| Temperature measurement monitoring / Range overshoot | 0x7FFF |
| Temperature measurement monitoring / Open circuit | 0x7FFF |
| Temperature measurement monitoring / General fault | 0x8000 |
| Temperature measurement monitoring / Open inputs | 0x7FFF |
| Resistance measurement monitoring / Range undershoot | 0x0000 |
| Resistance measurement monitoring / Range overshoot | 0xFFFF |
| Resistance measurement monitoring / Open circuit | 0xFFFF |
| Resistance measurement monitoring / General fault | 0xFFFF |
| Resistance measurement monitoring / Open inputs | 0xFFFF |
| Input | Resistance measurement with constant current supply for 2- or 4-wire connections |
| Digital converter resolution | 16-bit |
| Filter time | Configurable between 2 and 20 ms |
| Conversion procedure | Sigma-delta |
| Output format | INT or UINT for resistance measurement |
| Resistance measurement range | 0.1 to 4500 Ω / 0.05 to 2250 Ω |
| Sensor standard | EN 60751 |
| Common-mode range | ±1 VDC |
| Insulation voltage between channel and bus | 500 Veff |
| Linearization method | Software |
| Measuring current | 250 µA ±1.25% |
| Reference | 4530 Ω ±0.1% |
| Permissible input signal | Short-term max. ±30 V |
| Max. gain drift | 0.003 %/°C |
| Max. offset drift | 5.25 mΩ/°C |
| Nonlinearity | <0.002% |
| Crosstalk between channels | <-70 dB |
Electrical properties
| Electrical isolation | Channel isolated from bus Channel not isolated from channel |
Operating conditions
| Mounting orientation / Any | Yes |
| Installation elevation above sea level / 0 to 2000 m | No limitation |
| Installation elevation above sea level / >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP67 |
Ambient conditions
| Temperature / Operation | -25 to 60°C |
| Temperature / Derating | - |
| Temperature / Storage | -40 to 85°C |
| Temperature / Transport | -40 to 85°C |
Mechanical properties
| Dimensions / Width | 53 mm |
| Dimensions / Height | 85 mm |
| Dimensions / Depth | 42 mm |
| Torque for connections / M8 | Max. 0.4 Nm |
| Torque for connections / M12 | Max. 0.6 Nm |
| Weight | 200 g |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
Manuals
3D CAD models
ECAD / EPLAN
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.