B&R X67AT1402
4 inputs for thermocouple sensors Sensor types J, K, N, R and S Additional direct raw value measurement for other sensor types Terminal temperature compensation The module is a temperature module for type J, K, N, R and S thermocouple sensors. The selected sensor type is used for all 4 inputs.
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
Short description
| I/O module | 4 inputs for thermocouple sensors |
General information
| Diagnostics / Inputs | Yes, using LED status indicator and software |
| Diagnostics / I/O power supply | Yes, using LED status indicator and software |
| Connection type / X2X Link | M12, B-coded |
| Connection type / Inputs | 4x M12, A-coded |
| Connection type / I/O power supply | M8, 4-pin |
| Power consumption / Internal I/O | 2.6 W |
| Power consumption / X2X Link power supply | 0.75 W |
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / CRA (Cyber Resilience Act) | In preparation |
| Certifications / ATEX | Zone 2, II 3G Ex nA IIA T5 Gc IP67, Ta = 0 - Max. 60°C TÜV 05 ATEX 7201X |
| Certifications / UL | cULus E115267 Industrial control equipment |
| Certifications / HazLoc | cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
| Certifications / KC | Yes |
| B&R ID code | 0x1486 |
| Status indicators | I/O function per channel, supply voltage, bus function |
I/O power supply
| Nominal voltage | 24 VDC |
| Voltage range | 18 to 30 VDC |
| Integrated protective function | Reverse polarity protection |
Thermocouple temperature inputs
| Measurement range / Sensor temperature / Type J: Fe-CuNi | -210 to 1200°C |
| Measurement range / Sensor temperature / Type K: NiCr-Ni | -270 to 1372°C |
| Measurement range / Sensor temperature / Type N: NiCrSi-NiSi | -270 to 1300°C |
| Measurement range / Sensor temperature / Type S: PtRh10-Pt | -50 to 1768°C |
| Measurement range / Sensor temperature / Type R: PtRh13-Pt | -50 to 1768°C |
| Measurement range / Terminal temperature | -25 to 85°C |
| Measurement range / Raw value | ±65.534 mV |
| Resolution / Sensor temperature | 1 LSB = 0.1°C |
| Resolution / Terminal temperature | 1 LSB = 0.1°C |
| Resolution / Raw value output with respect to gain | 1 LSB = 1 µV or 2 µV |
| Normalization / Type J: Fe-CuNi | -210.0 to 1200.0°C |
| Normalization / Type K: NiCr-Ni | -270.0 to 1372.0°C |
| Normalization / Type N: NiCrSi-NiSi | -270.0 to 1300.0°C |
| Normalization / Type S: PtRh10-Pt | -50.0 to 1768.0°C |
| Normalization / Type R: PtRh13-Pt | -50.0 to 1768.0°C |
| Monitoring / Range undershoot | 0x8001 |
| Monitoring / Range overshoot | 0x7FFF |
| Monitoring / Open circuit | 0x7FFF |
| Monitoring / Open inputs | 0x7FFF |
| Monitoring / General fault | 0x8000 |
| Max. error at 25°C / Offset / Type J: Fe-CuNi | ±0.024% |
| Max. error at 25°C / Offset / Type K: NiCr-Ni | ±0.030% |
| Max. error at 25°C / Offset / Type N: NiCrSi-NiSi | ±0.035% |
| Max. error at 25°C / Offset / Type S: PtRh10-Pt | ±0.088% |
| Max. error at 25°C / Offset / Type R: PtRh13-Pt | ±0.078% |
| Max. error at 25°C / Gain | ±0.040% |
| Max. offset drift / Type J: Fe-CuNi | 0.0024%/°C |
| Max. offset drift / Type K: NiCr-Ni | 0.0030%/°C |
| Max. offset drift / Type N: NiCrSi-NiSi | 0.0035%/°C |
| Max. offset drift / Type S: PtRh10-Pt | 0.0089%/°C |
| Max. offset drift / Type R: PtRh13-Pt | 0.0079%/°C |
| Common-mode rejection / DC | >70 dB |
| Common-mode rejection / 50 Hz | >70 dB |
| Input filter / Cutoff frequency | 4 Hz / First-order filter |
| Input filter / Slope | -20 dB |
| Input | Thermocouple |
| Digital converter resolution | 16-bit |
| Filter time | Configurable between 2 and 20 ms |
| Output format | INT |
| Terminal temperature compensation | Using thermocouple connector X67AC9A02 (accessory) |
| Sensor standard | IEC 60584-1 |
| Conversion procedure | Sigma-delta |
| Linearization method | Software |
| Permissible input signal | Short-term ±30 VDC |
| Max. gain drift | 0.0123%/°C |
| Nonlinearity | <0.002% |
| Common-mode range | ±12 VDC |
| Crosstalk between channels | <-70 dB |
| Terminal temperature error | Typ. ±2°C after 10 min. |
| Insulation voltage between channel and bus | 500 Veff |
| Conversion time | 62 ms per channel with 50 Hz filter + 62 ms per cycle for terminal temperature measurement with 50 Hz filter |
Electrical properties
| Electrical isolation | Channel isolated from bus Channel not isolated from channel |
Operating conditions
| Mounting orientation / Any | Yes |
| Installation elevation above sea level / 0 to 2000 m | No limitation |
| Installation elevation above sea level / >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP67 |
Ambient conditions
| Temperature / Operation | -25 to 60°C |
| Temperature / Derating | - |
| Temperature / Storage | -40 to 85°C |
| Temperature / Transport | -40 to 85°C |
Mechanical properties
| Dimensions / Width | 53 mm |
| Dimensions / Height | 85 mm |
| Dimensions / Depth | 42 mm |
| Torque for connections / M8 | Max. 0.4 Nm |
| Torque for connections / M12 | Max. 0.6 Nm |
| Weight | 205 g |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
Manuals
3D CAD models
ECAD / EPLAN
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.