IAC

B&R X67BC8513.L12-1

POWERLINK V1/V2 Integrated hub for economical wiring 12 digital channels, configurable as inputs or outputs 1 analog input, 0 to 20 mA, 12-bit M8 connection type I/O configuration and firmware update via the fieldbus Integrated connection to the local expansion via X2X Link for up to 250 additional modules Configurable I/O cycle (starting at 200 µs) The bus controller makes it possible to connect X2X Link I/O nodes to POWERLINK. It is also possible to operate the X2X Link cycle synchronously 1:1 or synchronous to POWERLINK using a prescaler. Additional X2X Link I/O nodes (X67 modules or other modules based on X2X Link) can be connected using the integrated X2X Link connection. Mechanically, POWERLINK is connected via an IP67-rated standard D-coded M12 Ethernet connector. POWERLINK is a standard protocol for Fast Ethernet equipped with hard real-time characteristics. The POWERLINK Standardization Group (EPSG) ensures that the standard remains open and is continually developed:: www.ethernet-powerlink.org.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
Bus controllerPOWERLINK (V1/V2) controlled node
General information
B&R ID code / Bus controller0x046C
B&R ID code / Internal I/O module0x04A8
Diagnostics / OutputsYes, using LED status indicator and software
Diagnostics / I/O power supplyYes, using LED status indicator and software
Support / Dynamic node allocation (DNA)Yes
Connection type / FieldbusM12, D-coded
Connection type / X2X LinkM12, B-coded
Connection type / Inputs/Outputs8x M12, A-coded
Connection type / I/O power supplyM8, 4-pin
Power consumption / Fieldbus2.5 W
Power consumption / Internal I/O0.6 W
Power consumption / X2X Link power supply17.25 W at maximum power output for connected I/O modules
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Inputs/Outputs6 digital inputs, 6 digital outputs (not configurable), inputs with additional function, 1 analog channel
Insulation voltage between channel and bus500 Veff
Nominal voltage24 VDC
Sensor/Actuator power supply0.5 A summation current
Status indicatorsI/O function per channel, supply voltage, bus function
Power output15 W X2X Link power supply for I/O modules
Interfaces
Transfer / Physical layer100BASE-TX
Transfer / Half-duplexYes
Transfer / Full-duplexNo
Transfer / AutonegotiationYes
Transfer / Auto-MDI/MDIXYes
Min. cycle time / Fieldbus200 μs
Min. cycle time / X2X Link250 μs
FieldbusPOWERLINK (V1/V2) controlled node
TypeType 2
Variant2x M12 interface (hub), 2x female connector on module
Line lengthMax. 100 m between 2 stations (segment length)
Transfer rate100 Mbit/s
Hub propagation delay0.96 to 1 µs
Synchronization between bus systems possibleYes
I/O power supply
Power consumption / Sensor/Actuator power supplyMax. 12 W
Nominal voltage24 VDC
Voltage range18 to 30 VDC
Integrated protective functionReverse polarity protection
Sensor/Actuator power supply
VoltageI/O power supply minus voltage drop for short-circuit protection
Voltage drop for short-circuit protection at 0.5 AMax. 2 VDC
Summation currentMax. 0.5 A
Short-circuit proofYes
Digital inputs
Switching threshold / Low<5 VDC
Switching threshold / High>15 VDC
Input characteristics per EN 61131-2Type 1
Input voltage18 to 30 VDC
Input current at 24 VDCTyp. 4 mA
Input circuitSink
Input resistanceTyp. 6 kΩ
Edge detection / Time measurement
Counter frequency / Internal10 kHz
Signal formSquare wave pulse
Counter size16-bit
Pulse length>200 µs with 200 µs pause between pulses
Measurement typePropagation delay measurement between output and corresponding feedback input
Analog inputs
Output format / Current0x0000 - 0x7FFF / 1 LSB = 0x0008 = 4.883 μA
Output of digital value during overload / Undershoot0x0000
Output of digital value during overload / Overshoot0x7FFF
Max. error / Gain0.1%
Max. error / Offset0.05%
Common-mode rejection / DC>50 dB
Common-mode rejection / 50 Hz>50 dB
Input filter / Cutoff frequency1 kHz
Input filter / Slope40 dB
Input0 to 20 mA
Input typeDifferential input
Digital converter resolution12-bit
Conversion time200 µs
Output formatINT
Load<300 Ω
Input protectionProtection against wiring with supply voltage
Permissible input signalMax. ±30 mA
Conversion procedureSuccessive approximation
Max. gain drift0.013 %/°C
Max. offset drift0.02 %/°C
Common-mode range±2 V
Crosstalk between channels>70 dB
Nonlinearity<0.1%
Insulation voltage between input and bus500 Veff
Voltage drop at 20 mATyp. 4.5 V
Digital outputs
Switching delay / 0 → 1<400 µs
Switching delay / 1 → 0<400 µs
Switching frequency / Resistive loadMax. 100 Hz
Switching frequency / Inductive loadSee section "Switching inductive loads".
VariantCurrent-sourcing FET
Switching voltageI/O power supply minus residual voltage
Nominal output current0.5 A
Total nominal current8 A
Output circuitSource
Output protectionThermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads, reverse polarity protection of the output power supply
Diagnostic statusOutput monitoring with 10 ms delay
Leakage current when the output is switched off5 µA
Switching on after overload shutdownApprox. 10 ms (depends on the module temperature)
RDS(on)150 mΩ
Residual voltage<0.3 V at 0.5 A nominal current
Peak short-circuit current<12 A
Braking voltage when switching off inductive loads50 VDC
Electrical properties
Electrical isolationBus isolated from POWERLINK and channel Channel not isolated from channel
Operating conditions
Mounting orientation / AnyYes
Installation elevation above sea level / 0 to 2000 mNo limitation
Installation elevation above sea level / >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP67
Ambient conditions
Temperature / Operation-25 to 60°C
Temperature / Derating-
Temperature / Storage-40 to 85°C
Temperature / Transport-40 to 85°C
Mechanical properties
Dimensions / Width53 mm
Dimensions / Height155 mm
Dimensions / Depth42 mm
Torque for connections / M8Max. 0.4 Nm
Torque for connections / M12Max. 0.6 Nm
Weight360 g

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.