B&R X67BC8780.L12

POWERLINK 8 CAN interfaces M12 connections Integrated hub for efficient cabling This bus controller makes it possible to connect 8 CAN interfaces to the POWERLINK network. The CAN interfaces are operated via an integrated hub, which increases the total cable length defined by classical CAN bus topology. POWERLINK is a standard protocol for Fast Ethernet equipped with hard real-time characteristics. The Ethernet POWERLINK Standardization Group (EPSG) ensures openness and continuous development: www.ethernet-powerlink.org.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
Bus controllerPOWERLINK (V1/V2) controlled node
General information
B&R ID code / Bus controller0xED84
Diagnostics / OutputsYes, using LED status indicator and software
Diagnostics / Power supplyYes, using LED status indicator and software
Support / Dynamic node allocation (DNA)Yes
Connection type / FieldbusM12, D-coded
Connection type / Inputs/Outputs8x M12, A-coded
Connection type / I/O power supplyM8, 4-pin
Power consumption / Internal I/O2.5 W
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Inputs/Outputs8 CAN interfaces
Insulation voltage between channel and bus500 Veff
Nominal voltage24 VDC
Status indicatorsTX/RX per CAN interface, supply voltage, bus function
Fieldbus
Transfer / Physical layer100BASE-TX
Transfer / Half-duplexYes
Transfer / Full-duplexNo
Transfer / AutonegotiationYes
Transfer / Auto-MDI/MDIXYes
TypePOWERLINK (V1/V2) controlled node
Variant2x M12 interface (hub), 2x female connector on module
Line lengthMax. 100 m between 2 stations (segment length)
Transfer rate100 Mbit/s
Hub propagation delay0.96 to 1 µs
Cycle time200 µs
Interfaces
TypeCAN
Variant8x M12 interface (hub)
Max. distance1000 m
Transfer rateBus length ≤25 m: Max. 500 kbps Bus length ≤100 m: Max. 250 kbps Bus length ≤700 m: Max. 50 kbps
Hub propagation delay250 ns
Terminating resistorIntegrated in module
Sensor/Actuator power supply
Voltage9 to 32 V
Voltage drop for short-circuit protection at 0.5 AMax. 2 VDC
Summation currentMax. 1.6 A (200 mA per channel)
Short-circuit proofYes
Power supply
Nominal voltage24 VDC
Voltage range9 to 32 VDC
Reverse polarity protectionYes
Electrical properties
Electrical isolationPOWERLINK isolated from channel Channel not isolated from channel
Operating conditions
Mounting orientation / AnyYes
Installation elevation above sea level / 0 to 2000 mNo limitation
Installation elevation above sea level / >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP67
Ambient conditions
Temperature / Operation-25 to 60°C
Temperature / Derating-
Temperature / Storage-40 to 85°C
Temperature / Transport-40 to 85°C
Mechanical properties
Dimensions / Width53 mm
Dimensions / Height155 mm
Dimensions / Depth42 mm
Torque for connections / M8Max. 0.4 Nm
Torque for connections / M12Max. 0.6 Nm

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.