IAC

B&R X67DC2322

2 resolvers BRX/BRT evaluation 2 digital inputs and outputs for each The module is equipped with 2 resolver connections as well as 2 digital inputs and outputs for each. It is possible to evaluate BRX and BRT resolvers using a configurable sine gain of 1 or 0.25.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
I/O module2 resolver inputs, 2 digital inputs, 2 digital outputs
General information
Diagnostics / OutputsYes, using LED status indicator and software
Diagnostics / I/O power supplyYes, using LED status indicator and software
Connection type / X2X LinkM12, B-coded
Connection type / Inputs/OutputsM12, A-coded
Connection type / EncoderM12, 12-pin, A-coded
Connection type / I/O power supplyM8, 4-pin
Power consumption / Internal I/O1 W
Power consumption / X2X Link power supply0.75 W
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / ATEXZone 2, II 3G Ex nA IIA T5 Gc IP67, Ta = 0 - Max. 60°C TÜV 05 ATEX 7201X
Certifications / ULcULus E115267 Industrial control equipment
Certifications / HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
Certifications / KCYes
B&R ID code0xA5C7
Status indicatorsI/O function per channel, supply voltage, bus function
Additional power dissipation caused by actuators (resistive) [W]12.5 W
Resolver inputs
Reference output / Output voltageTyp. 4.4 Veff
Reference output / Output currentMax. 50 mAeff
Reference output / Frequency10 kHz
Resolver transformation ratio / BRX0.5 (±10%)
Resolver transformation ratio / BRT1 (±10%)
Quantity2
TypeDifferential
Angular position resolution14-bit
Short-circuit protection (reference output)Yes
Input impedance10.4 kΩ - j*11.1 kΩ
Resolver typeBRX / BRT
I/O power supply
Nominal voltage24 VDC
Voltage range18 to 30 VDC
Digital inputs
Input filter / Hardware≤20 µs
Input filter / Software-
Switching threshold / Low<5 V
Switching threshold / High>15 V
Quantity2
Nominal voltage24 VDC
Input current at 24 VDCTyp. 5 mA
Input circuitSink
Sensor power supply0.5 A summation current
Input delay<1 ms
Digital outputs
Switching delay / 0 → 1Max. 500 µs
Switching delay / 1 → 0Max. 500 µs
Switching frequency / Resistive loadMax. 100 Hz
Quantity2
Nominal voltage24 VDC
Nominal output current0.5 A
Total nominal current1 A
Output circuitSource
Output protectionThermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads, reverse polarity protection of the output power supply
Electrical properties
Electrical isolationChannel isolated from bus Channel not isolated from channel
Operating conditions
Mounting orientation / AnyYes
Installation elevation above sea level / 0 to 2000 mNo limitation
Installation elevation above sea level / >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP67
Ambient conditions
Temperature / Operation-25 to 60°C
Temperature / Derating-
Temperature / Storage-40 to 85°C
Temperature / Transport-40 to 85°C
Mechanical properties
Dimensions / Width53 mm
Dimensions / Height85 mm
Dimensions / Depth42 mm
Torque for connections / M8Max. 0.4 Nm
Torque for connections / M12Max. 0.6 Nm
Weight200 g

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.