IAC

B&R X67DO1332

8 A summation current per module All outputs with single-channel diagnostics for short circuit or overload Extremely short cycle times Outputs with short circuit protection Integrated protection for switching inductances The module is a digital output module for 24 VDC. It is equipped with 8 outputs for a source output circuit.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
I/O module8 digital outputs 24 VDC
General information
Diagnostics / OutputsYes, using LED status indicator and software
Diagnostics / I/O power supplyYes, using LED status indicator
Connection type / X2X LinkM12, B-coded
Connection type / Outputs8x M8, 3-pin
Connection type / I/O power supplyM8, 4-pin
Power consumption / Internal I/O2 W
Power consumption / X2X Link power supply0.75 W
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / ATEXZone 2, II 3G Ex nA IIA T5 Gc IP67, Ta = 0 - Max. 60°C TÜV 05 ATEX 7201X
Certifications / ULcULus E115267 Industrial control equipment
Certifications / HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
Certifications / KCYes
B&R ID code0x1467
Status indicatorsI/O function per channel, supply voltage, bus function
I/O power supply
Power consumption / Actuator power supplyMax. 12 W
Nominal voltage24 VDC
Voltage range18 to 30 VDC
Integrated protective functionReverse polarity protection
Digital outputs
Switching delay / 0 → 1<250 µs
Switching delay / 1 → 0<270 µs
Switching frequency / Resistive loadMax. 100 Hz
Continuous current per / OutputMax. 2 A
Continuous current per / GroupMax. 4 A (simultaneity factor = 50%)
Continuous current per / ModuleMax. 8 A
Quantity8
ExecutionCurrent-sourcing FET
Nominal voltage24 VDC
Switching voltageI/O power supply minus residual voltage
Nominal output current2 A
Total nominal current8 A
Output circuitSource
Output protectionThermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads, reverse polarity protection of the output power supply
Actuator power supply0.5 A summation current
Diagnostic statusOutput monitoring with 10 ms delay
Leakage current when the output is switched off5 µA
Switching on after overload shutdownApprox. 10 ms (depends on the module temperature)
Group 1Channels 1 to 4
Group 2Channels 5 to 8
Residual voltage<0.5 V at 2 A nominal current
Peak short-circuit current<21 A
Braking voltage when switching off inductive loads50 VDC
Actuator power supply
VoltageI/O power supply minus voltage drop for short-circuit protection
Voltage drop for short-circuit protection at 500 mAMax. 2 VDC
Summation currentMax. 0.5 A
Short-circuit proofYes
Electrical properties
Electrical isolationChannel isolated from bus Channel not isolated from channel
Operating conditions
Mounting orientation / AnyYes
Installation elevation above sea level / 0 to 2000 mNo limitation
Installation elevation above sea level / >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP67
Ambient conditions
Temperature / Operation-25 to 60°C
Temperature / DeratingSee section "Derating".
Temperature / Storage-40 to 85°C
Temperature / Transport-40 to 85°C
Mechanical properties
Dimensions / Width53 mm
Dimensions / Height85 mm
Dimensions / Depth42 mm
Torque for connections / M8Max. 0.4 Nm
Torque for connections / M12Max. 0.6 Nm
Weight180 g

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.