B&R X67PS1300
Electrical isolation of supply and X2X Link power supply Protection with redundancy during parallel operation of multiple system supply modules Short circuit protection Overload protection This system supply module converts the 24 VDC I/O supply voltage into the electrically isolated X2X Link power supply. The module provides 15 W of output power for additional X67 modules on the bus.
View on our store →Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
Short description
| System power supply modules | Galvanically isolated X2X Link power supply |
General information
| Connection type / X2X Link power supply output | M12, B-coded |
| Connection type / X2X Link power supply input | M8, 4-pin |
| Power consumption / Internal | 3 W |
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / CRA (Cyber Resilience Act) | In preparation |
| Certifications / ATEX | Zone 2, II 3G Ex nA IIA T5 Gc IP67, Ta = 0 - Max. 60°C TÜV 05 ATEX 7201X |
| Certifications / UL | cULus E115267 Industrial control equipment |
| Certifications / HazLoc | cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
| Certifications / KC | Yes |
| Status indicators | Input voltage OK, output voltage OK |
X2X Link power supply input
| Nominal voltage | 24 VDC |
| Voltage range | 18 to 30 VDC |
| Nominal current | 0.75 A |
| Fuse | Integrated |
X2X Link power supply output
| Nominal voltage | 20 VDC |
| Nominal current | 0.75 A |
| Nominal output power | 15 W |
| Efficiency | >80% |
| Parallel connection | Yes |
| Redundant operation | Yes, with equal input voltages |
| Supply failure bridging | >5 ms at 24 VDCIn and IOut = 0.75 A |
| Overload characteristics | Short-circuit proof, overload-proof |
| Insulation voltage between input and output | 500 Veff |
I/O power supply
| Nominal voltage | 24 VDC |
| Voltage range | 18 to 30 VDC |
| Integrated protective function | Reverse polarity protection |
Electrical properties
| Electrical isolation | X2X Link supply isolated from X2X Link power supply |
Operating conditions
| Mounting orientation / Any | Yes |
| Installation elevation above sea level / 0 to 2000 m | No limitation |
| Installation elevation above sea level / >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP67 |
Ambient conditions
| Temperature / Operation | -25 to 60°C |
| Temperature / Derating | - |
| Temperature / Storage | -40 to 85°C |
| Temperature / Transport | -40 to 85°C |
Mechanical properties
| Dimensions / Width | 53 mm |
| Dimensions / Height | 85 mm |
| Dimensions / Depth | 42 mm |
| Torque for connections / M8 | Max. 0.4 Nm |
| Torque for connections / M12 | Max. 0.6 Nm |
| Weight | 225 g |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
Manuals
3D CAD models
ECAD / EPLAN
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.