IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
Short description
I/O module
35 digital inputs, 6 analog inputs, 45 digital outputs, 4 analog outputs, 8 thermocouples, 2 PWM outputs
Interfaces
2x Ethernet, 1x CAN bus, 1x RS485 interface, 1x USB
General information
System requirements / Automation Studio
4.5.01 or later
System requirements / Automation Runtime
B4.53 or later
LEDs / Quantity
7
LEDs / State
Supply voltage OK, operating state, module status, Ethernet, CAN, RS485
Controller redundancy / Master capability
No
Support / ACOPOS support
No
Support / Visual Components support
No
Support / Safety support
No
Certifications / CE
Yes
Certifications / CRA (Cyber Resilience Act)
In preparation
B&R ID code
0xF733
Cooling
Passive
Power button
No
Reset button
Yes
Buzzer
No
Electrical isolation
Thermocouples, Ethernet 1 (IF2) and Ethernet 2 (IF3) isolated from each other and from other interfaces
Power supply not isolated from channel, and channel not isolated from channel
Controller
Processor / L1 cache / Data code
24 kB
Processor / L1 cache / Program code
32 kB
Processor / Type
ARM Cortex-A9
Processor / Clock frequency
667 MHz
Processor / L2 cache
256 kB
Standard memory / RAM
512 MB DDR3 SDRAM
Application memory / Writable data amount / Guaranteed
40 TB
Application memory / Writable data amount / Results for 5 years
Counter inputs 1 to 2: <4 µs
Inputs 3 to 33: <1 ms
Event counters
Quantity
2
Signal form
Square wave pulse
Evaluation
Positive or negative edge, cyclic counter
Input frequency
Max. 100 kHz
Pulse length
>4 µs
Counter size
16-bit
Supported inputs
Input 1: Counter 1
Input 2: Counter 2
Gate time measurement
Counter frequency / Internal
48 MHz, 12 MHz, 3 MHz, 750 kHz
Counter frequency / External
Max. 100 kHz
Quantity
2
Signal form
Square wave pulse
Evaluation
Positive or negative edge
Counter size
16-bit
Input frequency
Max. 100 kHz
Length of pause between pulses
10 µs
Pulse length
10 µs
Supported inputs
Input 1: Counter 1
Input 2: Counter 2
Period measurement
Counter frequency / Internal
48 MHz, 12 MHz, 3 MHz, 750 kHz
Counter frequency / External
Max. 100 kHz
Quantity
2
Signal form
Square wave pulse
Supported inputs
Input 1: Counter 1
Input 2: Counter 2
Input frequency
Max. 100 kHz
Evaluation
Positive or negative edge
Counter size
16-bit
Analog inputs
Output format / Data type
INT
Output format / Voltage
Inputs 1 and 2: INT 0x8000 - 0x7FFF / 1 LSB = 0x0004 = 1.22 mV
Inputs 3 to 6: INT 0x0000 - 0x7FFF / 1 LSB = 0x0004 = 1.22 mV
Output format / Current
Inputs 3 to 6: INT 0x0000 - 0x7FFF / 1 LSB = 0x0008 = 4.88 µA
Max. error / Voltage / Gain
0.1%
Max. error / Voltage / Offset
0.025%
Max. error / Current / Gain
0.12%
Max. error / Current / Offset
0.05%
Max. gain drift / Voltage
0.006%/°C
Max. gain drift / Current
0.009%/°C
Max. offset drift / Voltage
0.002%/°C
Max. offset drift / Current
0.004 %/°C
Input filter / Cutoff frequency
Inputs 1 and 2: 1 kHz
Inputs 3 to 6: 10 kHz
Input filter / Slope
60 dB
Input
Inputs 1 and 2: ±10 V
Inputs 3 to 6: 0 to 10 V, 0 to 20 mA or 0 to 100% (Upot)
Input type
Inputs 1 and 2: Differential input
Inputs 3 to 6: Single-ended input
Digital converter resolution
14-bit
Input impedance in signal range
10 MΩ
Current channel load
<400 Ω
Input protection
Protection against wiring with supply voltage
Supply voltage UPot for potentiometer
4.5 V / Max. 50 mA
Measurement range
0.5 to 10 kΩ
Thermocouple temperature inputs
Measurement range / Sensor temperature / FeCuNi: Type J
-210 to 1200°C
Measurement range / Sensor temperature / NiCrNi: Type K
-270 to 1372°C
Measurement range / Sensor temperature / NiCrSi: Type N
-270 to 1300°C
Measurement range / Sensor temperature / PtRhPt: Type S
-50 to 1768°C
Measurement range / Voltage
±70 mV
Resolution / Sensor temperature
0.1°C/LSB
Resolution / Voltage
2.136 µV/LSB
Basic accuracy / Type J: Fe-CuNi
±0.14% at 25°C
Basic accuracy / Type K: NiCr-Ni
±0.18% at 25°C
Basic accuracy / Type N: NiCrSi-NiSi
±0.16% at 25°C
Basic accuracy / Type S: PtRh10-Pt
±0.34% at 25°C
Terminal temperature compensation / Internal
Yes
Terminal temperature compensation / Basic accuracy at 25°C not taking Pt1000 sensor into account
±2°C after 10 minutes
Quantity
8
Digital converter resolution
16-bit
Output format
INT
Digital outputs
Actuator power supply / Supply
External
Actuator power supply / Fuse
No internal fuse, the power supply of the outputs of each connector must be protected using a separate fuse of max. 15 A.
Quantity
45
Nominal output current
Screw clamp terminal blocks X12, X13 and X15:
Per output: 2 A
Per group: 2 A
Per screw clamp terminal block: 11 A
Screw clamp terminal blocks X14 and X16:
Per output: 0.5 A
Output circuit
Sink
Output protection
Short circuit and overload protection
Switching frequency (resistive load)
Max. 100 Hz
Switching delay
Max. 500 µs
Type
Low-side driver (Sink)
Supply voltage
Separately for each connector: 12 to 24 VDC ±20%
PWM output
Load / Resistive load
≥8 Ω
Load / Inductive load
≤10 mH
PWM pulse width / PWM mode
15-bit + sign
≥1 µs
PWM pulse width / Current mode
15-bit + sign
Quantity
2
Type
Push/Pull
Supply voltage (permissible range)
External, 11 to 28 VDC
Nominal current
3 A
Maximum load current
3.5 A / output
PWM frequency
15 Hz to 50 kHz
Output protection
Reverse polarity protection for supply voltage, must be protected externally
Configurable dither
Amplitude (8-bit), frequency (2 to 500 Hz)
Period duration resolution
16-bit
Analog outputs
Max. error / Gain
0.080%, based on the current output value
Max. error / Offset
0.050%, based on the entire output range
Output format / Data type
INT
Output format / Voltage
INT 0x8000 - 0x7FFF / 1 LSB = 0x0010 = 4.88 mV
Range of values / 10 V
0x7FFF
Range of values / 0 V
0x0000
Range of values / -10 V
0x8000
Quantity
4
Output
±10 V
Digital converter resolution
12-bit
Switch on/off behavior
Internal enable relay, for startup
Output protection
Protection against wiring with supply voltage, short-circuit proof
Max. load per output
±10 mA (load ≥1 kΩ)
Max. gain drift
0.08%, based on the current output value
Max. offset drift
0.05%, based on the entire output range
Error caused by load change
0.015% from 10 MΩ → 1 kΩ, resistive
Nonlinearity
0.025%, based on the output range
Power supply unit
Voltage range
24 VDC ±25%
Power consumption
3.5 W
Voltage monitoring
Yes
Operating conditions
Mounting orientation / Horizontal
No
Mounting orientation / Vertical
Yes
Pollution degree per EN 60664-1
2
Ambient conditions
Temperature / Operation
0 to 50°C
Temperature / Storage
-40 to 85°C
Temperature / Transport
-40 to 85°C
Relative humidity / Operation
10 to 90%, non-condensing
Relative humidity / Storage
5 to 95%, non-condensing
Relative humidity / Transport
5 to 95%, non-condensing
Mechanical properties
Dimensions / Width
190 mm
Dimensions / Height
198 mm
Dimensions / Depth
31 mm
Module dimensions including mounting plates
190 x 198 x 31 mm (W x H x D)
Documentation & CAD