Altivar Process ATV600 Drive — Códigos de alarme
Os códigos de falha detectados aparecem no terminal gráfico de exibição.
| Código | Alarme |
|---|---|
| ACF1 | AFE DC-Caps Error |
| ACF2 | AFE Current Control Error |
| ACF3 | AFE Line Filter Error |
| AFLF | Adv.Function Lock |
| ASF | Angle error |
| CBF | Circuit Breaker Error |
| CFA | CabinetCirc A Error |
| CFB | CabinetCirc B Error |
| CFC | CabinetCirc C Error |
| CFF | Incorrect Config |
| CFI | Invalid Config |
| CFI2 | Conf Transfer Error |
| CFI3 | Pre-settings Transfer Error |
| CHF | Cabinet Overheat Error |
| CNF | Fdbus Com Interrupt |
| COF | CANopen Com Interrupt |
| COPF | Cooling Pump Error |
| CRF1 | Precharge Capa |
| CRF3 | AFE contactor feedback error |
| CSF | Channel Switch Error |
| DCRE | DC Bus Ripple Error |
| DRYF | Dry Run Error |
| EEF1 | Ctrl Memory Error |
| EEF2 | Pwr Memory Error |
| EPF1 | External Error |
| EPF2 | Fieldbus Error |
| ETHF | Embd Eth Com Interrupt |
| FCF1 | Out Contact Closed Error |
| FCF2 | Out Contact Opened Error |
| FDR1 | FDR 1 Error |
| FDR2 | FDR 2 Error |
| FFDF | Fan Feedback Error |
| FWER | FW Update Error |
| HCF | Boards Compat |
| HFPF | High Flow Error |
| IDLF | Egy Saving Exit Error |
| IFA | MonitorCirc A Error |
| IFB | MonitorCirc B Error |
| IFC | MonitorCirc C Error |
| IFD | MonitorCirc D Error |
| IHF | Input Overheating |
| ILF | Internal Link Error |
| INF0 | Internal Error 0 |
| INF1 | Internal Error 1 |
| INF2 | Internal Error 2 |
| INF3 | Internal Error 3 |
| INF4 | Internal Error 4 |
| INF6 | Internal Error 6 |
| INF7 | Internal Error 7 |
| INF8 | Internal Error 8 |
| INF9 | Internal Error 9 |
| INFA | Internal Error 10 |
| INFB | Internal Error 1 1 |
| INFC | Internal Error 12 |
| INFD | Internal Error 13 |
| INFE | Internal Error 14 |
| INFF | Internal Error 15 |
| INFG | Internal Error 16 |
| INFH | Internal Error 17 |
| INFK | Internal Error 20 |
| INFL | Internal Error 21 |
| INFM | Internal Error 22 |
| INFN | Internal Error 23 |
| INFP | Internal Error 25 |
| INFR | Internal Error 27 |
| INFS | Internal Error 28 |
| INFT | Internal Error 29 |
| INFU | Internal Error 30 |
| INFV | Internal Error 31 |
| IPPF | Inlet Pres Error |
| JAMF | Anti Jam Error |
| LCF | Input Contactor |
| LCHF | High Level Error |
| LCLF | Low Level Error |
| LFF1 | AI1 4-20 mA loss |
| LFF2 | AI2 4-20mA loss |
| LFF3 | AI3 4-20mA loss |
| LFF4 | AI4 4-20mA loss |
| LFF5 | AI5 4-20 mA loss |
| LKON | ON Lock Error |
| MDLF | MultiDrive Link Error |
| MFF | Mains Freq Out Of Range |
| MOF | Module Overheat |
| MPDF | M/P Device Error |
| MPLF | Lead Pump Error |
| OBF | DC Bus OverV |
| OBF2 | AFE Bus unbalancing |
| OCF | Overcurrent |
| OHF | Device Overheat |
| OLC | Process Overload |
| OLF | Motor Overload |
| OPF1 | Single out ph loss |
| OPF2 | Output Ph Loss |
| OPHF | Out Pressure High |
| OPLF | Out Pressure Low |
| OSF | Supply Mains OverV |
| P24C | Cab I/O 24V Error |
| PCPF | PumpCycle start Error |
| PFMF | PID Fdbk Error |
| PGLF | Prog Load Error |
| PGRF | Prog Run Error |
| PHF | Input Phase Loss |
| PLFF | Pump Low Flow Error |
| SAFF | Safety Func Error |
| SCF1 | Motor short circuit |
| SCF3 | Ground Short Circuit |
| SCF4 | IGBT Short Circuit |
| SCF5 | Mot Short Circuit |
| SCF6 | AFE ShortCircuit error |
| SLF1 | Mdb Com Interrupt |
| SLF2 | PC Com Interrupt |
| SLF3 | HMI Com Interruption |
| SOF | Motor Overspeed |
| SPFC | Security Files Corrupt |
| STF | Motor Stall Error |
| T2CF | AI2 Th Sensor Err |
| T3CF | AI3 Th Sensor Err |
| T4CF | AI4 Th Sensor Err |
| T5CF | AI5 Th Sensor Err |
| TFA | MotorWinding A Error |
| TFB | MotorWinding B Error |
| TFC | MotorBearing A Error |
| TFD | MotorBearing B Error |
| TH2F | AI2 Th Level Error |
| TH3F | AI3 Th Level Error |
| TH4F | AI4 Th Level Error |
| TH5F | AI5 Th Level Error |
| TJF | Device Overheat |
| TJF2 | AFE IGBT over-heat error |
| TNF | Autotuning Error |
| ULF | Proc Underload |
| URF | AFE Mains Undervoltage |
| USF | Supply Mains UnderV |
| VCF | VxCtrl Error |