IAC

VFD Cross-Reference

Enter a variable frequency drive model number and see candidate equivalents across 12 brands (4,034 drives indexed) — matched on voltage class, standard power rating, and overload duty, from official manufacturer ratings tables. Or size a drive from your motor nameplate below. IAC is an authorized distributor for Benshaw, Invertek, LS Electric and Toshiba.

Siemens: 1,506Invertek: 511WEG: 376Benshaw: 316Fuji Electric: 295Yaskawa: 268Allen-Bradley: 245Mitsubishi: 197Toshiba: 129ABB: 111Schneider Electric: 55LS Electric: 25
CIMR-AU4A0018
Yaskawa A1000 · 460V-3ph-in · 5.5 kW · 14.8 A · NEMA1

Invertek equivalents (11)

LS Electric equivalents (1)

  • 0055H100-4H100 · 5.5 kW · 7.5 HP · 12 A · IP20 · normal duty · 232×160×181 mm, 3.3 kgnormal duty — verify overload sizing

Toshiba equivalents (4)

  • VFAS3-4055PCVF-AS3 · 5.5 kW · 7.5 HP · 12.7 A · IP20 · heavy duty · 391.5×155×231 mm, 7.7 kg
  • VFMB1-4055PLVF-MB1 · 5.5 kW · 14.3 A · IP20 · heavy duty · 220×150×232 mm, 4.3 kg
  • VFS15-4055PL-WVF-S15 · 5.5 kW · 14.3 A · IP20 · heavy duty · 220×150×170 mm, 3.9 kg
  • VFS15-4055PL-W1VF-S15 · 5.5 kW · 14.3 A · IP20 · heavy duty · 220×150×170 mm, 3.9 kg

Benshaw equivalents (3)

  • RSI-007-GM2-4CRSi GM2 · 5.5 kW · 7.5 HP · 10 A · IP20 · normal duty · 183×135×150.5 mm, 1.98 kgnormal duty — verify overload sizing
  • VFD-RSI-007-H2-4CRSi H2 · 5.5 kW · 7.5 HP · 12 A · IP20 · normal duty · 232×160×181 mm, 3.3 kgnormal duty — verify overload sizing
  • RSi-007-SG-4BRSi SG · 5.5 kW · 7.5 HP · 12 A · NEMA1 · normal dutynormal duty — verify overload sizing

Allen-Bradley equivalents (6)

  • 22B-D012F104PowerFlex 40 · 5.5 kW · 7.5 HP · 12 A · IP20 · heavy duty · 260×130×180 mm, 4.3 kg
  • 22B-D012N104PowerFlex 40 · 5.5 kW · 7.5 HP · 12 A · IP20 · heavy duty · 260×130×180 mm, 4.3 kg
  • 25A-D013N104PowerFlex 523 · 5.5 kW · 7.5 HP · 13 A · IP20 · heavy duty · 220×109×184 mm, 2.3 kg
  • 25A-D013N114PowerFlex 523 · 5.5 kW · 7.5 HP · 13 A · IP20 · heavy duty · 220×109×184 mm, 2.3 kg
  • 25B-D013N104PowerFlex 525 · 5.5 kW · 7.5 HP · 13 A · IP20 · heavy duty · 220×109×184 mm, 2.3 kg
  • 25B-D013N114PowerFlex 525 · 5.5 kW · 7.5 HP · 13 A · IP20 · heavy duty · 220×109×184 mm, 2.3 kg

ABB equivalents (3)

  • ACS550-01-012A-4ACS550 · 5.5 kW · 7.5 HP · 11.9 A · IP21 · normal duty · 330×125×212 mm, 6.5 kgnormal duty — verify overload sizing
  • ACS580-01-12A6-4ACS580 · 5.5 kW · 7.5 HP · 12.6 A · IP21 · normal duty · 330×125×223 mm, 4.6 kgnormal duty — verify overload sizing
  • ACS550-U1-012A-4ACS550 · 5.5 kW · 7.5 HP · 11.9 A · NEMA1 · normal duty · 330×125×212 mm, 6.5 kgnormal duty — verify overload sizing

Fuji Electric equivalents (11)

  • FRN0013C2E-4FRENIC-Mini (C2) · 5.5 kW · 7.5 HP · 13 A · IP20 · heavy duty · 285×181.5×208 mm, 4.6 kg
  • FRN0013C2S-4FRENIC-Mini (C2) · 5.5 kW · 7.5 HP · 13 A · IP20 · heavy duty · 220×180×158 mm, 3.1 kg
  • FRN0018G2E-4GFRENIC-MEGA (G2) · 5.5 kW · 7.5 HP · 13.5 A · IP20 · heavy duty · 260×220×195 mm, 6.6 kg
  • FRN0018G2S-4GFRENIC-MEGA (G2) · 5.5 kW · 7.5 HP · 13.5 A · IP20 · heavy duty · 260×220×195 mm, 5.9 kg
  • FRN0022E2E-4FRENIC-Ace (E2) · 5.5 kW · 7.5 HP · IP20 · heavy duty
  • FRN0022E2S-4FRENIC-Ace (E2) · 5.5 kW · 7.5 HP · IP20 · heavy duty
  • FRN007E1S-4UFRENIC-Multi (E1S) · 7.5 HP · 13 A · IP20 · heavy duty · 220×180×158 mm
  • FRN007G1H-4UFRENIC-MEGA (G1H) · 7.5 HP · 13.5 A · IP20 · heavy duty · 320×220×270 mm, 10.8 kg
  • FRN007G1S-4UFRENIC-MEGA (G1S) · 7.5 HP · 13.5 A · IP20 · heavy duty · 260×220×195 mm, 6.5 kg
  • FRN010G1H-4UFRENIC-MEGA (G1H) · 7.5 HP · 13.5 A · IP20 · heavy duty · 320×220×270 mm, 10.8 kg

Schneider Electric equivalents (1)

  • ATV320U55N4BAltivar Machine ATV320 · 5.5 kW · 7.5 HP · 14.3 A · IP20 · heavy duty · 232×150×232 mm, 7.5 kg

WEG equivalents (9)

  • CFW320C11P0T4DB20CFW320 · 7.5 HP · 11 A · IP20 · heavy duty · 214×89×164 mm, 1.5 kg
  • CFW320C11P0T4NB20CFW320 · 7.5 HP · 11 A · IP20 · heavy duty · 214×89×164 mm, 1.5 kg
  • CFW500B10P0T4DB20G2CFW500-G2 · 7.5 HP · 10 A · IP20 · heavy duty · 200.7×101.6×160 mm, 1.18 kg
  • CFW900A14P0T4DB20Y2BCFW900 · 7.5 HP · 12 A · IP20 · heavy duty · 269.2×144.8×221 mm, 4.49 kg
  • CFW110013T4O55DSZCFW11 · 7.5 HP · 11 A · IP55 · heavy duty · 528.3×271.8×279.4 mm, 17.01 kg
  • CFW500A10P0T4DB66DSG2CFW500-G2 · 7.5 HP · 10 A · IP66 · heavy duty · 264.2×165.1×251.5 mm, 9.98 kg
  • CFW500A10P0T4DB66G2CFW500-G2 · 7.5 HP · 10 A · IP66 · heavy duty · 264.2×165.1×226.1 mm, 9.98 kg
  • CFW110013T4ON1ZCFW11 · 7.5 HP · 11 A · NEMA1 · heavy duty · 307.3×147.3×228.6 mm, 9.98 kg
  • CFW501B10P0T4DB20C3CFW501 · 7.5 HP · 10 A · IP20 · normal duty · 200.7×101.6×160 mm, 1.22 kgnormal duty — verify overload sizing

Mitsubishi equivalents (5)

  • FR-A840-00170FR-A800 · 5.5 kW · 12 A · IP20 · heavy duty · 260×220×170 mm, 6.7 kg
  • FR-D740-5.5KFR-D700 · 5.5 kW · 12 A · IP20 · heavy duty · 220×150×155 mm, 3.3 kg
  • FR-E740-5.5KFR-E700 · 5.5 kW · 12 A · IP20 · heavy duty · 220×150×147 mm, 3.2 kg
  • FR-E840-0120FR-E800 · 5.5 kW · 12 A · IP20 · heavy duty · 150×220×147 mm, 2.4 kg
  • FR-F740-5.5KFR-F700 · 5.5 kW · 11.5 A · IP20 · normal duty · 260×150×140 mm, 3.5 kgnormal duty — verify overload sizing

Siemens equivalents (54)

Candidate matches by voltage class, standard power step and duty; the footprint badge means the candidate fits within the source drive envelope (width and height, ±2 mm, from official dimension tables) — always confirm control features, I/O, and dimensions against the datasheets before substituting. Sources: official manufacturer ratings tables.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs Yaskawa parts — new, refurbished, or exchange units with warranty.

Don't have a drive model? Size from the motor.

Enter nameplate values (or photograph the plate). We size on continuous current (FLA × service factor × duty margin), then list matching VFDs — authorized brands first.

Input phases *

Motor sizing FAQ

What do I read on the nameplate?
Look for horsepower (HP) or kilowatts (kW), full-load amps (FLA or rated current), supply voltage, and service factor (SF). FLA is the most reliable gate for drive current — use it when it is printed.
Why does service factor matter?
SF is how much continuous overload the motor can deliver (often 1.15). The drive must cover motor power × SF × application margin, not nameplate HP alone.
When should I call instead?
Multi-motor buses, regenerative loads, long motor cables, extreme ambient temperature, or crane duty with unusual overload cycles — call 877-727-8757 for application engineering. This tool returns candidates, not a certified selection.