IAC

VFD Cross-Reference

Enter a variable frequency drive model number and see candidate equivalents across 12 brands (4,034 drives indexed) — matched on voltage class, standard power rating, and overload duty, from official manufacturer ratings tables. Or size a drive from your motor nameplate below. IAC is an authorized distributor for Benshaw, Invertek, LS Electric and Toshiba.

Siemens: 1,506Invertek: 511WEG: 376Benshaw: 316Fuji Electric: 295Yaskawa: 268Allen-Bradley: 245Mitsubishi: 197Toshiba: 129ABB: 111Schneider Electric: 55LS Electric: 25
CIMR-AU4A0165
Yaskawa A1000 · 460V-3ph-in · 75 kW · 150 A · NEMA1

Invertek equivalents (4)

LS Electric equivalents (1)

  • 0750H100-4H100 · 75 kW · 100 HP · 142 A · IP20 · normal duty · 550×325×309 mm, 43 kgnormal duty — verify overload sizing

Toshiba equivalents (1)

  • VFAS3-4750PCVF-AS3 · 75 kW · 100 HP · 145 A · IP20 · heavy duty · 908×265×313 mm, 59.5 kg

Benshaw equivalents (14)

  • MX4PB-HD-100-4-4-HBMX4PB · 100 HP · 124 A · NEMA4/12 · heavy duty · 914.4×762×406.4 mm, 99.8 kg
  • MX4PB-HD-100-4-4-NCMX4PB · 100 HP · 124 A · NEMA4/12 · heavy duty · 914.4×762×406.4 mm, 99.8 kg
  • CSXi-075-V6-C1CSXi · 100 HP · 140 A · IP00 · normal dutynormal duty — verify overload sizing
  • EMX4e-0184B-V5-C1-HEMX4e · 100 HP · 124 A · IP00 · normal dutynormal duty — verify overload sizing
  • EMX4e-0200B-V5-C1-HEMX4e · 100 HP · 131 A · IP00 · normal dutynormal duty — verify overload sizing
  • EMX4i-0184B-V5-C1-HEMX4i · 100 HP · 124 A · IP00 · normal duty · 495×216×245 mm, 12.7 kgnormal duty — verify overload sizing
  • EMX4i-0200B-V5-C1-HEMX4i · 100 HP · 131 A · IP00 · normal duty · 495×216×245 mm, 12.7 kgnormal duty — verify overload sizing
  • VFD-RSI-100-H2-4CRSi H2 · 75 kW · 100 HP · 142 A · IP20 · normal duty · 550×325×309 mm, 43 kgnormal duty — verify overload sizing
  • RSi-100-SG-4BRSi SG · 75 kW · 100 HP · 152 A · NEMA1 · normal dutynormal duty — verify overload sizing
  • CSXi-0125-4-PP-N3R-CB-PDCSXi Pump Panel · 100 HP · 140 A · NEMA3R · normal dutynormal duty — verify overload sizing

ABB equivalents (4)

  • ACS550-01-157A-4ACS550 · 75 kW · 125 HP · 157 A · IP21 · normal duty · 700×302×400 mm, 69 kgnormal duty — verify overload sizing
  • ACS580-01-145A-4ACS580 · 75 kW · 100 HP · 145 A · IP21 · normal duty · 727×252×369 mm, 42.4 kgnormal duty — verify overload sizing
  • ACS550-U1-125A-4ACS550 · 100 HP · 125 A · NEMA1 · normal duty · 602×265×286 mm, 34 kgnormal duty — verify overload sizing
  • ACS550-U1-157A-4ACS550 · 75 kW · 125 HP · 157 A · NEMA1 · normal duty · 700×302×400 mm, 69 kgnormal duty — verify overload sizing

Fuji Electric equivalents (5)

  • FRN0203E2E-4FRENIC-Ace (E2) · 75 kW · 100 HP · IP00 · heavy duty
  • FRN0203E2S-4FRENIC-Ace (E2) · 75 kW · 100 HP · IP00 · heavy duty
  • FRN0217G2E-4GFRENIC-MEGA (G2) · 75 kW · 100 HP · 150 A · IP00 · heavy duty · 837.5×355×270 mm, 38 kg
  • FRN0217G2S-4GFRENIC-MEGA (G2) · 75 kW · 100 HP · 150 A · IP00 · heavy duty · 740×355×270 mm, 38 kg
  • FRN125G1S-4UFRENIC-MEGA (G1S) · 100 HP · 150 A · IP00 · heavy duty · 740×355×270 mm, 42 kg

WEG equivalents (4)

  • CFW500G0142T4DB20G2CFW500-G2 · 100 HP · 115 A · IP20 · heavy duty · 675.6×335.3×315 mm, 51.98 kg
  • CFW500G0142T4NB20G2CFW500-G2 · 100 HP · 115 A · IP20 · heavy duty · 675.6×335.3×315 mm, 51.98 kg
  • CFW900D0146T4DB20Y2BCFW900 · 100 HP · 124 A · IP20 · heavy duty · 624.8×248.9×294.6 mm, 33.48 kg
  • CFW900D0146T4NB20Y2BCFW900 · 100 HP · 124 A · IP20 · heavy duty · 624.8×248.9×294.6 mm, 33.48 kg

Mitsubishi equivalents (2)

  • FR-A840-02160FR-A800 · 75 kW · 144 A · IP00 · heavy duty · 620×465×300 mm, 52 kg
  • FR-F740-75KFR-F700 · 75 kW · 144 A · IP00 · normal duty · 260×220×170 mm, 6.5 kgnormal duty — verify overload sizing

Siemens equivalents (38)

Candidate matches by voltage class, standard power step and duty; the footprint badge means the candidate fits within the source drive envelope (width and height, ±2 mm, from official dimension tables) — always confirm control features, I/O, and dimensions against the datasheets before substituting. Sources: official manufacturer ratings tables.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs Yaskawa parts — new, refurbished, or exchange units with warranty.

Don't have a drive model? Size from the motor.

Enter nameplate values (or photograph the plate). We size on continuous current (FLA × service factor × duty margin), then list matching VFDs — authorized brands first.

Input phases *

Motor sizing FAQ

What do I read on the nameplate?
Look for horsepower (HP) or kilowatts (kW), full-load amps (FLA or rated current), supply voltage, and service factor (SF). FLA is the most reliable gate for drive current — use it when it is printed.
Why does service factor matter?
SF is how much continuous overload the motor can deliver (often 1.15). The drive must cover motor power × SF × application margin, not nameplate HP alone.
When should I call instead?
Multi-motor buses, regenerative loads, long motor cables, extreme ambient temperature, or crane duty with unusual overload cycles — call 877-727-8757 for application engineering. This tool returns candidates, not a certified selection.