VFD Cross-Reference
Enter a variable frequency drive model number and see candidate equivalents across 12 brands (4,034 drives indexed) — matched on voltage class, standard power rating, and overload duty, from official manufacturer ratings tables. Or size a drive from your motor nameplate below. IAC is an authorized distributor for Benshaw, Invertek, LS Electric and Toshiba.
Invertek equivalents (9)
- ODE-3-120043-1012ODE-3 · 0.75 kW · 1 HP · 4.3 A · IP20 · heavy duty · 173×83×123 mm, 1 kglarger: +45mm H
- ODE-3-120043-1F12ODE-3 · 0.75 kW · 1 HP · 4.3 A · IP20 · heavy duty · 173×83×123 mm, 1 kglarger: +45mm H
- ODP-2-22010-1HF42-MNODP-2 · 1 HP · 4.3 A · IP20
- ODP-2-22075-1KF42-MNODP-2 · 0.75 kW · 4.3 A · IP20
- ODV-3-220043-1F12-MNODV-3 · 0.75 kW · 1 HP · 4.3 A · IP20
- ODP-2-22010-1HF4A-MNODP-2 · 1 HP · 4.3 A · IP66
- ODP-2-22010-1HF4B-MNODP-2 · 1 HP · 4.3 A · IP66
- ODV-3-220043-1F1A-MNODV-3 · 0.75 kW · 1 HP · 4.3 A · IP66
- ODV-3-220043-1F1E-MNODV-3 · 0.75 kW · 1 HP · 4.3 A · IP66
Toshiba equivalents (4)
- VFMB1S-2007PLVF-MB1 · 0.75 kW · 4.8 A · IP20 · heavy duty · 270×45×232 mm, 1.8 kglarger: +142mm H / +95mm D
- VFNC3S-2007PLVF-nC3 · 0.75 kW · 4.2 A · IP20 · heavy duty · 130×72×131 mm, 0.8 kgfits footprint
- VFS15S-2007PL-WVF-S15 · 0.75 kW · 4.8 A · IP20 · heavy duty · 130×72×135 mm, 1.1 kgfits footprint
- VFS15S-2007PL-W1VF-S15 · 0.75 kW · 4.8 A · IP20 · heavy duty · 130×72×135 mm, 1.1 kgfits footprint
Allen-Bradley equivalents (14)
- 22A-A3P6F103PowerFlex 4 · 0.75 kW · 1 HP · 3.6 A · IP20 · heavy duty · 152×80×136 mm, 1.4 kglarger: +24mm H
- 22A-A3P6N103PowerFlex 4 · 0.75 kW · 1 HP · 3.6 A · IP20 · heavy duty · 152×80×136 mm, 1.4 kglarger: +24mm H
- 22A-A3P6N113PowerFlex 4 · 0.75 kW · 1 HP · 3.6 A · IP20 · heavy duty · 152×80×136 mm, 1.4 kglarger: +24mm H
- 22A-A4P5F104PowerFlex 4 · 0.75 kW · 1 HP · 4.5 A · IP20 · heavy duty · 152×80×136 mm, 1.4 kglarger: +24mm H
- 22A-A4P5N104PowerFlex 4 · 0.75 kW · 1 HP · 4.5 A · IP20 · heavy duty · 152×80×136 mm, 1.4 kglarger: +24mm H
- 22A-A4P5N114PowerFlex 4 · 0.75 kW · 1 HP · 4.5 A · IP20 · heavy duty · 152×80×136 mm, 1.4 kglarger: +24mm H
- 22B-A5P0F104PowerFlex 40 · 0.75 kW · 1 HP · 5 A · IP20 · heavy duty · 180×100×136 mm, 2.2 kglarger: +52mm H
- 22B-A5P0N104PowerFlex 40 · 0.75 kW · 1 HP · 5 A · IP20 · heavy duty · 180×100×136 mm, 2.2 kglarger: +52mm H
- 22B-A5P0N114PowerFlex 40 · 0.75 kW · 1 HP · 5 A · IP20 · heavy duty · 180×100×136 mm, 2.2 kglarger: +52mm H
- 25A-A4P8N104PowerFlex 523 · 0.75 kW · 1 HP · 4.8 A · IP20 · heavy duty · 152×72×172 mm, 1.1 kglarger: +24mm H / +35mm D
Fuji Electric equivalents (5)
- FRN0005E2E-7FRENIC-Ace (E2) · 0.75 kW · 1 HP · IP20 · heavy duty
- FRN0005E2S-7FRENIC-Ace (E2) · 0.75 kW · 1 HP · IP20 · heavy duty
- FRN0006C2E-7FRENIC-Mini (C2) · 0.75 kW · 1 HP · 5.5 A · IP20 · heavy duty · 180×110×139 mm, 1.2 kglarger: +52mm H
- FRN0006C2S-7FRENIC-Mini (C2) · 0.75 kW · 1 HP · 5.5 A · IP20 · heavy duty · 120×80×140 mm, 0.9 kgfits footprint
- FRN001E1S-7UFRENIC-Multi (E1S) · 1 HP · 5 A · IP20 · heavy duty · 120×80×152 mmfits footprint
Schneider Electric equivalents (2)
- ATV320U07M2BAltivar Machine ATV320 · 0.75 kW · 1 HP · 4.8 A · IP20 · heavy duty · 325×45×245 mm, 2.4 kglarger: +197mm H / +108mm D
- ATV320U07M2CAltivar Machine ATV320 · 0.75 kW · 1 HP · 4.8 A · IP20 · heavy duty · 143×72×138 mm, 1.1 kglarger: +15mm H
WEG equivalents (2)
- CFW100C04P2S220G2CFW100-G2 · 1 HP · 4.2 A · IP20 · heavy duty · 127×55.9×129.5 mm, 0.64 kgfits footprint
- CFW320A04P2S2NB20CFW320 · 1 HP · 4.2 A · IP20 · heavy duty · 157.9×70×148.4 mm, 0.9 kglarger: +30mm H / +11mm D
Mitsubishi equivalents (3)
- FR-D720S-0.75KFR-D700 · 0.75 kW · 4.2 A · IP20 · heavy duty · 128×68×162.5 mm, 1.1 kgfits footprint
- FR-E720S-0.75KFR-E700 · 0.75 kW · 5 A · IP20 · heavy duty · 128×108×135.5 mm, 1.4 kgfits footprint
- FR-E820S-0050FR-E800 · 0.75 kW · 5 A · IP20 · heavy duty · 128×108×135 mm, 1.3 kgfits footprint
Candidate matches by voltage class, standard power step and duty; the footprint badge means the candidate fits within the source drive envelope (width and height, ±2 mm, from official dimension tables) — always confirm control features, I/O, and dimensions against the datasheets before substituting. Sources: official manufacturer ratings tables.
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs Yaskawa parts — new, refurbished, or exchange units with warranty.
Don't have a drive model? Size from the motor.
Enter nameplate values (or photograph the plate). We size on continuous current (FLA × service factor × duty margin), then list matching VFDs — authorized brands first.
Motor sizing FAQ
- What do I read on the nameplate?
- Look for horsepower (HP) or kilowatts (kW), full-load amps (FLA or rated current), supply voltage, and service factor (SF). FLA is the most reliable gate for drive current — use it when it is printed.
- Why does service factor matter?
- SF is how much continuous overload the motor can deliver (often 1.15). The drive must cover motor power × SF × application margin, not nameplate HP alone.
- When should I call instead?
- Multi-motor buses, regenerative loads, long motor cables, extreme ambient temperature, or crane duty with unusual overload cycles — call 877-727-8757 for application engineering. This tool returns candidates, not a certified selection.