IAC

VFD Cross-Reference

Enter a variable frequency drive model number and see candidate equivalents across 12 brands (4,034 drives indexed) — matched on voltage class, standard power rating, and overload duty, from official manufacturer ratings tables. Or size a drive from your motor nameplate below. IAC is an authorized distributor for Benshaw, Invertek, LS Electric and Toshiba.

Siemens: 1,506Invertek: 511WEG: 376Benshaw: 316Fuji Electric: 295Yaskawa: 268Allen-Bradley: 245Mitsubishi: 197Toshiba: 129ABB: 111Schneider Electric: 55LS Electric: 25
GA50U2056ABA
Yaskawa GA500 · 230V-3ph-in · 20 HP · 56 A · IP20

Invertek equivalents (7)

LS Electric equivalents (1)

  • 0150H100-2H100 · 15 kW · 20 HP · 56 A · IP20 · normal duty · 290×180×205.3 mm, 4.6 kg

Toshiba equivalents (3)

  • VFAS3-2150PVF-AS3 · 15 kW · 20 HP · 63.4 A · IP20 · heavy duty · 660×210×268 mm, 27.3 kg
  • VFS15-2150PM-WVF-S15 · 15 kW · 66 A · IP20 · heavy duty · 310×180×190 mm, 6.9 kg
  • VFS15-2150PM-W1VF-S15 · 15 kW · 66 A · IP20 · heavy duty · 310×180×190 mm, 6.9 kg

Benshaw equivalents (6)

  • VFD-RSI-020-H2-2CRSi H2 · 15 kW · 20 HP · 56 A · IP20 · normal duty · 290×180×205.3 mm, 4.6 kg
  • RSi-020-SG-2BRSi SG · 15 kW · 20 HP · 60 A · NEMA1 · normal duty
  • MX4PB-HD-020-2-4-HBMX4PB · 20 HP · 54 A · NEMA4/12 · heavy duty · 609.6×508×304.8 mm, 79.4 kg
  • MX4PB-HD-020-2-4-NCMX4PB · 20 HP · 54 A · NEMA4/12 · heavy duty · 609.6×508×304.8 mm, 79.4 kg
  • MX4PB-SD-020-2-4-HBMX4PB · 20 HP · 54 A · NEMA4/12 · normal duty · 609.6×508×304.8 mm, 79.4 kg
  • MX4PB-SD-020-2-4-NCMX4PB · 20 HP · 54 A · NEMA4/12 · normal duty · 609.6×508×304.8 mm, 79.4 kg

ABB equivalents (2)

  • ACS550-01-059A-2ACS550 · 15 kW · 20 HP · 59.4 A · IP21 · normal duty · 490×203×231 mm, 16 kg
  • ACS550-U1-059A-2ACS550 · 15 kW · 20 HP · 59.4 A · NEMA1 · normal duty · 490×203×231 mm, 16 kg

Fuji Electric equivalents (7)

  • FRN0060C2S-2FRENIC-Mini (C2) · 15 kW · 20 HP · 60 A · IP20 · heavy duty · 260×220×190 mm, 4.5 kg
  • FRN0069E2E-2FRENIC-Ace (E2) · 15 kW · 20 HP · IP20 · heavy duty
  • FRN0069E2S-2FRENIC-Ace (E2) · 15 kW · 20 HP · IP20 · heavy duty
  • FRN0075G2S-2GFRENIC-MEGA (G2) · 15 kW · 20 HP · 63 A · IP20 · heavy duty · 400×250×195 mm, 11 kg
  • FRN020E1S-2UFRENIC-Multi (E1S) · 20 HP · 60 A · IP20 · heavy duty · 260×220×195 mm
  • FRN025G1H-2UFRENIC-MEGA (G1H) · 20 HP · 63 A · IP20 · heavy duty · 460×250×270 mm, 17.3 kg
  • FRN025G1S-2UFRENIC-MEGA (G1S) · 20 HP · 63 A · IP20 · heavy duty · 400×250×195 mm, 9.5 kg

Schneider Electric equivalents (1)

  • ATV320D15M3CAltivar Machine ATV320 · 15 kW · 20 HP · 66 A · IP20 · heavy duty · 330×180×198 mm, 6.9 kg

WEG equivalents (8)

  • CFW500E56P0T2DB20G2CFW500-G2 · 20 HP · 56 A · IP20 · heavy duty · 350.5×221×193 mm, 10.02 kg
  • CFW500F77P0T2DB20G2CFW500-G2 · 20 HP · 64 A · IP20 · heavy duty · 548.6×299.7×254 mm, 25.99 kg
  • CFW110054T2O55DSZCFW11 · 20 HP · 45 A · IP55 · heavy duty · 670.6×307.3×348 mm, 30.03 kg
  • CFW110070T2O55DSZCFW11 · 20 HP · 56 A · IP55 · heavy duty · 670.6×307.3×348 mm, 30.03 kg
  • CFW500C56P0T2DB66DSG2CFW500-G2 · 20 HP · 56 A · IP66 · heavy duty · 475×320×315 mm, 20.41 kg
  • CFW500C56P0T2DB66G2CFW500-G2 · 20 HP · 56 A · IP66 · heavy duty · 475×320×289.6 mm, 20.41 kg
  • CFW110054T2ON1ZCFW11 · 20 HP · 45 A · NEMA1 · heavy duty · 449.6×221×292.1 mm, 20.87 kg
  • CFW110070T2ON1ZCFW11 · 20 HP · 56 A · NEMA1 · heavy duty · 449.6×221×292.1 mm, 20.87 kg

Mitsubishi equivalents (5)

  • FR-A820-00770FR-A800 · 15 kW · 61 A · IP20 · heavy duty · 400×250×190 mm, 15.5 kg
  • FR-D720-15KFR-D700 · 15 kW · 58 A · IP20 · heavy duty · 128×108×135.5 mm, 1.4 kg
  • FR-E720-15KFR-E700 · 15 kW · 60 A · IP20 · heavy duty · 128×108×135.5 mm, 1.4 kg
  • FR-E820-0600FR-E800 · 15 kW · 60 A · IP20 · heavy duty · 260×220×190 mm, 5.6 kg
  • FR-F720-15KFR-F700 · 15 kW · 58 A · IP20 · normal duty · 260×110×125 mm, 2.2 kg

Candidate matches by voltage class, standard power step and duty; the footprint badge means the candidate fits within the source drive envelope (width and height, ±2 mm, from official dimension tables) — always confirm control features, I/O, and dimensions against the datasheets before substituting. Sources: official manufacturer ratings tables.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs Yaskawa parts — new, refurbished, or exchange units with warranty.

Don't have a drive model? Size from the motor.

Enter nameplate values (or photograph the plate). We size on continuous current (FLA × service factor × duty margin), then list matching VFDs — authorized brands first.

Input phases *

Motor sizing FAQ

What do I read on the nameplate?
Look for horsepower (HP) or kilowatts (kW), full-load amps (FLA or rated current), supply voltage, and service factor (SF). FLA is the most reliable gate for drive current — use it when it is printed.
Why does service factor matter?
SF is how much continuous overload the motor can deliver (often 1.15). The drive must cover motor power × SF × application margin, not nameplate HP alone.
When should I call instead?
Multi-motor buses, regenerative loads, long motor cables, extreme ambient temperature, or crane duty with unusual overload cycles — call 877-727-8757 for application engineering. This tool returns candidates, not a certified selection.