IAC

VFD Cross-Reference

Enter a variable frequency drive model number and see candidate equivalents across 12 brands (4,034 drives indexed) — matched on voltage class, standard power rating, and overload duty, from official manufacturer ratings tables. Or size a drive from your motor nameplate below. IAC is an authorized distributor for Benshaw, Invertek, LS Electric and Toshiba.

Siemens: 1,506Invertek: 511WEG: 376Benshaw: 316Fuji Electric: 295Yaskawa: 268Allen-Bradley: 245Mitsubishi: 197Toshiba: 129ABB: 111Schneider Electric: 55LS Electric: 25
GA50UB012ABA
Yaskawa GA500 · 230V-1ph-in · 3 HP · 12.2 A · IP20

Invertek equivalents (11)

Toshiba equivalents (4)

  • VFMB1S-2022PLVF-MB1 · 2.2 kW · 11 A · IP20 · heavy duty · 270×60×232 mm, 2.2 kg
  • VFNC3S-2022PLVF-nC3 · 2.2 kW · 10 A · IP20 · heavy duty · 130×105×156 mm, 1.5 kg
  • VFS15S-2022PL-WVF-S15 · 2.2 kW · 11 A · IP20 · heavy duty · 130×105×150 mm, 1.6 kg
  • VFS15S-2022PL-W1VF-S15 · 2.2 kW · 11 A · IP20 · heavy duty · 130×105×150 mm, 1.6 kg

Allen-Bradley equivalents (10)

  • 22A-A9P6F103PowerFlex 4 · 2.2 kW · 3 HP · 9.6 A · IP20 · heavy duty · 180×100×136 mm, 2.2 kg
  • 22A-A9P6N103PowerFlex 4 · 2.2 kW · 3 HP · 9.6 A · IP20 · heavy duty · 180×100×136 mm, 2.2 kg
  • 22A-A9P6N113PowerFlex 4 · 2.2 kW · 3 HP · 9.6 A · IP20 · heavy duty · 180×100×136 mm, 2.2 kg
  • 22B-A012F104PowerFlex 40 · 2.2 kW · 3 HP · 12 A · IP20 · heavy duty · 260×130×180 mm, 4.3 kg
  • 22B-A012N104PowerFlex 40 · 2.2 kW · 3 HP · 12 A · IP20 · heavy duty · 260×130×180 mm, 4.3 kg
  • 22B-A012N114PowerFlex 40 · 2.2 kW · 3 HP · 12 A · IP20 · heavy duty · 260×130×180 mm, 4.3 kg
  • 25A-A011N104PowerFlex 523 · 2.2 kW · 3 HP · 11 A · IP20 · heavy duty · 180×87×172 mm, 1.6 kg
  • 25A-A011N114PowerFlex 523 · 2.2 kW · 3 HP · 11 A · IP20 · heavy duty · 180×87×172 mm, 1.6 kg
  • 25B-A011N104PowerFlex 525 · 2.2 kW · 3 HP · 11 A · IP20 · heavy duty · 180×87×172 mm, 1.6 kg
  • 25B-A011N114PowerFlex 525 · 2.2 kW · 3 HP · 11 A · IP20 · heavy duty · 180×87×172 mm, 1.6 kg

Fuji Electric equivalents (5)

  • FRN0011E2E-7FRENIC-Ace (E2) · 2.2 kW · 3 HP · IP20 · heavy duty
  • FRN0011E2S-7FRENIC-Ace (E2) · 2.2 kW · 3 HP · IP20 · heavy duty
  • FRN0012C2E-7FRENIC-Mini (C2) · 2.2 kW · 3 HP · 12 A · IP20 · heavy duty · 245×140×182 mm, 3 kg
  • FRN0012C2S-7FRENIC-Mini (C2) · 2.2 kW · 3 HP · 12 A · IP20 · heavy duty · 180×140×139 mm, 1.8 kg
  • FRN003E1S-7UFRENIC-Multi (E1S) · 3 HP · 11 A · IP20 · heavy duty · 180×140×151 mm

Schneider Electric equivalents (2)

  • ATV320U22M2BAltivar Machine ATV320 · 2.2 kW · 3 HP · 11 A · IP20 · heavy duty · 325×60×245 mm, 2.9 kg
  • ATV320U22M2CAltivar Machine ATV320 · 2.2 kW · 3 HP · 11 A · IP20 · heavy duty · 142×105×158 mm, 1.6 kg

WEG equivalents (6)

  • CFW320B10P0B2DB20CFW320 · 3 HP · 10 A · IP20 · heavy duty · 198.9×70×158.4 mm, 1.34 kg
  • CFW500B10P0B2DB20G2CFW500-G2 · 3 HP · 10 A · IP20 · heavy duty · 200.7×101.6×160 mm, 1.18 kg
  • CFW900A10P0B2DB20Y2BCFW900 · 3 HP · 10 A · IP20 · heavy duty · 269.2×144.8×221 mm, 4.49 kg
  • CFW500A10P0B2DB66DSG2CFW500-G2 · 3 HP · 10 A · IP66 · heavy duty · 264.2×165.1×251.5 mm, 9.98 kg
  • CFW500A10P0B2DB66G2CFW500-G2 · 3 HP · 10 A · IP66 · heavy duty · 264.2×165.1×226.1 mm, 9.98 kg
  • CFW110010S2ON1ZCFW11 · 3 HP · 10 A · NEMA1 · heavy duty · 307.3×147.3×228.6 mm, 6.3 kg

Mitsubishi equivalents (3)

  • FR-D720S-2.2KFR-D700 · 2.2 kW · 10 A · IP20 · heavy duty · 150×140×145 mm, 2 kg
  • FR-E720S-2.2KFR-E700 · 2.2 kW · 11 A · IP20 · heavy duty · 150×140×155.5 mm, 2 kg
  • FR-E820S-0110FR-E800 · 2.2 kW · 11 A · IP20 · heavy duty · 128×140×142.5 mm, 1.9 kg

Candidate matches by voltage class, standard power step and duty; the footprint badge means the candidate fits within the source drive envelope (width and height, ±2 mm, from official dimension tables) — always confirm control features, I/O, and dimensions against the datasheets before substituting. Sources: official manufacturer ratings tables.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs Yaskawa parts — new, refurbished, or exchange units with warranty.

Don't have a drive model? Size from the motor.

Enter nameplate values (or photograph the plate). We size on continuous current (FLA × service factor × duty margin), then list matching VFDs — authorized brands first.

Input phases *

Motor sizing FAQ

What do I read on the nameplate?
Look for horsepower (HP) or kilowatts (kW), full-load amps (FLA or rated current), supply voltage, and service factor (SF). FLA is the most reliable gate for drive current — use it when it is printed.
Why does service factor matter?
SF is how much continuous overload the motor can deliver (often 1.15). The drive must cover motor power × SF × application margin, not nameplate HP alone.
When should I call instead?
Multi-motor buses, regenerative loads, long motor cables, extreme ambient temperature, or crane duty with unusual overload cycles — call 877-727-8757 for application engineering. This tool returns candidates, not a certified selection.