SIMODRIVE 611 digital Drive System — Kode alarm
Kegagalan drive SIMODRIVE 611 digital dilaporkan sebagai alarm 6 digit (300000-301799) pada layar CNC SINUMERIK (Diagnosis -> Alarms); nomor axis/drive muncul pada parameter teks alarm.
Manual referensi (bahasa Inggris): 6FC5298-7AA20-0BP3 — Siemens SINUMERIK 840D/810D & SIMODRIVE 611 digital Diagnostics Manual (11/2006)
| Kode | Alarm |
|---|---|
| 300007 | Axis %1 drive %2 not present or inactive |
| 300008 | Axis %1 drive %2 measuring circuit %3 is not available |
| 300009 | Axis %1 drive %2 measuring circuit %3 wrong measuring circuit type (type %4 used) |
| 300010 | Axis %1 drive %2 active without NC axis assignment |
| 300011 | Axis %1 drive %2 hardware version of spindle not supported |
| 300012 | Axis %1 drive %2 hardware version of control module not supported |
| 300020 | Drive %1 removed for diagnostics |
| 300100 | Drive power failure |
| 300101 | Bus communications failure |
| 300200 | Drive bus hardware fault |
| 300201 | Axis %1 drive %2 timeout during access, error location %3 |
| 300202 | Axis %1 drive %2 CRC error, error location %3 |
| 300300 | Axis %1 drive %2 boot error, error code %3 |
| 300400 | Axis %1 drive %2 system error, error codes %3, %4 |
| 300401 | Drive software for type %1, block %2 missing or incorrect |
| 300402 | System error in drive link. Error codes %1, %2 |
| 300403 | Axis %1 drive %2 drive software and drive MD with different version numbers |
| 300404 | Axis %1 drive %2 drive MD contains different drive number |
| 300405 | Axis %1 drive %2 unknown drive alarm, code %3 |
| 300406 | Problem in the non-cyclic communication for basic address %1, additional information %2, %3, %4 |
| 300410 | Axis %1 drive %2 error when storing a file (%3, %4) |
| 300411 | Axis %1 drive %2 error when reading a file (%3, %4) |
| 300412 | Error when storing a file (%1, %2) |
| 300413 | Error when reading a file (%1, %2) |
| 300423 | Measuring results could not be read (%1) |
| 300500 | Axis %1 drive %2 system error, error codes %3, %4 |
| 300501 | Axis %1 drive %2 maximum current monitoring |
| 300502 | Axis %1 drive %2 maximum current monitoring of phase current R |
| 300503 | Axis %1 drive %2 maximum current monitoring of phase current S |
| 300706 | Axis %1 drive %2 monitoring cycle time invalid |
| 300707 | Axis %1 drive %2 basic cycle times of axes differ |
| 300708 | Axis %1 drive %2 current controller cycle times of axes differ |
| 300709 | Axis %1 drive %2 speed controller cycle times of axes differ |
| 300710 | Axis %1 drive %2 position controller cycle times of axes differ |
| 300711 | Axis %1 drive %2 monitoring cycle times of axes differ |
| 300712 | Axis %1 drive %2 configuration of controller structure (higher dynamic response) not possible |
| 300713 | Axis %1 drive %2 lead time for position controller invalid |
| 300714 | Axis %1 drive %2 power section code invalid |
| 300715 | Axis %1 drive %2 maximum power section current less than or equal to zero |
| 300716 | Axis %1 drive %2 torque constant less than or equal to zero |
| 300717 | Axis %1 drive %2 motor moment of inertia less than or equal to zero |
| 300718 | Axis %1 drive %2 calculation dead time of current controller less than or equal to zero |
| 300719 | Axis %1 drive %2 motor not parameterized for delta operation |
| 300720 | Axis %1 drive %2 maximum motor speed invalid |
| 300721 | Axis %1 drive %2 zero-load current greater than rated motor current |
| 300722 | Axis %1 drive %2 zero-load motor current greater than rated current of power section |
| 300723 | Axis %1 drive %2 STS configuration of axes differ |
| 300724 | Axis %1 drive %2 number of pole pairs invalid |
| 300737 | Axis %1 drive %2 configuration of two EnDat encoders not possible |
| 300738 | Axis %1 drive %2 module number for measuring system not possible |
| 300739 | Axis %1 drive %2 measuring system already used as motor measuring system |
| 300740 | Axis %1 drive %2 measuring system used several times |
| 300741 | Axis %1 drive %2 asynchronous mode: feedforward control gain out of range |
| 300742 | Axis %1 drive %2 voltage/frequency mode: converter frequency invalid |
| 300743 | Axis %1 drive %2 function not supported on this 611D controller module |
| 300744 | Axis %1 drive %2 safety monitoring checksum invalid, confirmation and acceptance test required! |
| 300745 | Axis %1 drive %2 limit values for safe end positions exchanged |
| 300746 | Axis %1 drive %2 SBH/SG not enabled |
| 300747 | Axis %1 drive %2 monitoring cycle time MD 1300 invalid |
| 300788 | Axis %1 drive %2 parameterization error in current control adaption |
| 300789 | Axis %1 drive %2 function not supported on this 611D controller module |
| 300790 | Axis %1, drive %2 Changeover speed/velocity too small |
| 300799 | Axis %1 drive %2 data backup and reboot required |
| 300850 | Axis %1 drive %2 parameterization error in speed control adaption |
| 300854 | Axis %1 drive %2 signal number of var. signaling function invalid |
| 300855 | Axis %1 drive %2 voltage/frequency mode: motor is turning |
| 300858 | Axis %1 drive %2 generator mode: response voltage > switch-off threshold |
| 300859 | Axis %1 drive %2 generator mode: response voltage > monitoring threshold |
| 300860 | Axis %1 drive %2 generator mode: emergency retraction speed > max. motor speed |
| 300861 | Axis %1 drive %2 generator mode : minimum axis speed > max. motor speed |
| 300862 | Axis %1 drive %2 emergency retraction mode/generator mode already active |
| 300863 | Axis %1 drive %2 emergency retraction mode/generator mode invalid |
| 300864 | Axis %1 drive %2 emergency retraction mode/generator mode not possible |
| 300865 | Axis %1 drive %2 measurement of DC link voltage not possible |
| 300875 | Axis %1 drive %2 fixed link voltage of axes differ |
| 300888 | Axis %1 drive %2 parameterization error in current control adaption |
| 300950 | Axis %1 drive %2 is not safely referenced |
| 300951 | Axis %1 drive %2 test stop is running |
| 300952 | Axis %1 drive %2 acceptance test is active |
| 301701 | Axis %1 drive %2 limit value for safe velocity too large |
| 301702 | Axis %1 drive %2 track inversion incorrect |
| 301703 | Axis %1 drive %2 encoder/motor type are not compatible |
| 301704 | Axis %1 drive %2 pole pair width/division of linear scale (internal) out of range |
| 301705 | Axis %1 drive %2 distance-coded scale incorrectly parameterized |
| 301706 | Axis %1 drive %2 parameterization of cam position invalid |
| 301707 | Axis %1 drive %2 parameterization of modulo value for safe cam (SN) invalid |
| 301708 | Axis %1 drive %2 actual value synchronisation not allowed |
| 301709 | Axis %1 drive %2 submodule with integrated linearization invalid |
| 301710 | Axis %1 drive %2 resolution SSI motor measuring system invalid |
| 301711 | Axis %1 drive %2 transmission length SSI motor measuring system invalid |
| 301712 | Axis %1 drive %2 multiturn SSI motor measuring system invalid |
| 301713 | Axis %1 drive %2 resolution SSI direct measuring system invalid |
| 301714 | Axis %1 drive %2 transmission length SSI direct measuring system invalid |
| 301715 | Axis %1 drive %2 multiturn SSI direct measuring system invalid |
| 301716 | Axis %1 drive %2 SSI direct measuring system without incremental signals not possible |
| 301717 | Axis %1 drive %2 SSI transmission timeout |